Instance still alive after cross in Sequence Diagram #45

Open nus-pe-bot opened 6 months ago

nus-pe-bot commented 6 months ago

Note from the teaching team: This bug was reported during the Part II (Evaluating Documents) stage of the PE. You may reject this bug if it is not related to the quality of documentation.


Screenshot 2024-04-19 at 5.31.32 PM.png

I believe you could simply omit the cross, and it will still be standard-compliant.


[original: nus-cs2113-AY2324S2/pe-interim#43] [original labels: severity.Low type.DocumentationBug]

ZMinghuiZ commented 6 months ago

Team's Response

Thank you for the response!

For SubLogic such as MiniGame, its instance or memory will be cleared after done executing. The reason that the lifeline still alive after cross is because the limitation of the drawing software, we have mentioned in note section below the diagram.

image.png

Duplicate status (if any):

--