Closed SavannahDearing closed 4 years ago
Example capabilitystatement: https://www.medentmobiletest.com/fhir/R4/metadata/index.php?medent_practice_id=savcw235
For test USCCAP-05: Capability Statement lists support for required US Core Profiles
There are multiple Observation profiles, but the R4 CapabilityStatement does not allow multiple "profile" elements: http://hl7.org/fhir/R4/capabilitystatement.html
Does Inferno recognize the "supportedProfile" elements for this test? Or is there another way to express this?
Hello Savannah: Yes Inferno looks both profile and supportedProfile.
Example capabilitystatement: https://www.medentmobiletest.com/fhir/R4/metadata/index.php?medent_practice_id=savcw235
For test USCCAP-05: Capability Statement lists support for required US Core Profiles
There are multiple Observation profiles, but the R4 CapabilityStatement does not allow multiple "profile" elements: http://hl7.org/fhir/R4/capabilitystatement.html
Does Inferno recognize the "supportedProfile" elements for this test? Or is there another way to express this?