Enclosure Configuration:
OA at Bay 1 is connected to interconnect in bay 8 and interconnect is connected top of the rack switch.
OA at bay 2 is connected to interconnect in bay 7 and this interconnect is connected top of the rack switch.
Steps to recreate:
Remove any one interconnect from bay 7 and 8.
Run Openhpid and get hpisensor out into a file.
Insert already removed interconnect and remove existing interconnect.
wait for 5 to 10 min and take hpisensor output in to a file.
Now compare the two hpisnor logs.
After all the above steps you can see the issue in hpisensor taken in 4th step will have no sensor readings.
Enclosure Configuration: OA at Bay 1 is connected to interconnect in bay 8 and interconnect is connected top of the rack switch. OA at bay 2 is connected to interconnect in bay 7 and this interconnect is connected top of the rack switch.
Steps to recreate:
Reported by: HemanthBeecherla
Original Ticket: openhpi/bugs/1992