The power saving is implemented by switching off transmitters.
In some device implementations, switching off transmitters can be treated as maintenance activity that gets automatically reversed after a maintenance period has passed.
In some future release, it is to be checked, whether it would be feasible and beneficial to combine switching off transmitters with the maintenance timer.
The vendor-specific characteristics of the maintenance timer implementations have to be taken into account.
The power saving is implemented by switching off transmitters.
In some device implementations, switching off transmitters can be treated as maintenance activity that gets automatically reversed after a maintenance period has passed.
In some future release, it is to be checked, whether it would be feasible and beneficial to combine switching off transmitters with the maintenance timer. The vendor-specific characteristics of the maintenance timer implementations have to be taken into account.