openBackhaul / equipment

Equipment for an Ethernet PHY interface according to IEEE 802.3
Apache License 2.0
1 stars 0 forks source link

ActualEquipment :: temperature Default value #46

Open openBackhaul opened 7 months ago

openBackhaul commented 7 months ago

No default value defined in the ONF CoreIM.

The temperature of the physical components would be of interest, e.g. to monitor the conditions on site.

A default value should be defined for being represented, if the hardware would not provide a temperature value for the associated component.

Potential Proposal: The two entries for the temperature in the two tables in §31 of chapter 9 of the TransmitterEquipment Spec. shall be complemented with the following statement "Only if the device would not provide the required information, "Temperature not yet provided." shall be represented as a default."

openBackhaul commented 7 months ago

Decision during the LF ONMI x-haul call on 24th of April 2024: The temperature may not be supported as a concept by the vendor or not be available due to unavailability on the device. A default value shall be defined to harmonize the handling of such situations across implementations.

openBackhaul commented 5 months ago

Has been updated in Equipment_3.0.0-tsi.240515.1100+spec.1.doc