Issue with measured values(temp and humidity) from BME280 and DHT22, why this happens #821

Open krasigarchev opened 3 years ago

krasigarchev commented 3 years ago

Dear team,

I'm realy new in github and IoT, please help me whith this issue. DHT22 and BME280 has diference in measured values. You can found me here or in telegram @Krasi_Garchev

Sensor Parameter Value SDS011 PM2.5 16.3 μg / m2 SDS011 PM10 24.2 μg / m2

DHT22 Temperature 12.7 ° C DHT22 Air humidity 99.9%

BME280 Temperature 10.9 ° C BME280 Atmospheric pressure 1004.23 hPa BME280 Air humidity 84.7%

WiFi Signal strength -49 dBm WiFi Signal quality 100%

pjgueno commented 3 years ago

The DHT22 almost always blocks at 99,9% after a while. It is the reason why we advise people to use the BME280 which works a lot better.

ricki-z commented 3 years ago

Another factor is the location of the sensors inside the case. The electronic part are creating some heat so that the upper part of the case is normally warmer than the lower part.

linuxlurak commented 3 years ago

Would you actually place the BME280 inside the sensor? Or are you talking specifically of the airrohr version with a HT Bogen? I placed it normally outside my own boxes (no HT-Bogen) with some kind of weather protection.

On a hackerspace website I saw they placed the BME280 inside a case. Not sure why as it only measures the enclosed environment of the sensor inside the box.

Some of my BME280 report extreme values at random points (at least I can't detect a trigger for this). Humidity sinks to 0, Temp to -140°C or something... No Idea why. Perhaps just some faulty Sensors? I got them very cheap from ali.

imaluschi commented 3 years ago

If you place the temperature sensor (DHT or BMP/BME) inside the case (box), you have at least 3°C more due to power consumption of the ESP. Can't say how the measurements will change in a box only for BME.

Concerning the issue with wrong values of BME you can find something here: #739 In my opinion it's a problem with I2C. I built 4 airrohr-sensors with SDS011, DNMS, BME280. In two cases (one is my own) DHT in addition. The problem occured in all 4 airrohr-sensors, even tough i replaced the BME in two different sensors. I also can't detect a trigger. In most cases, the airrohr firmware get stuck after some time. For the last airrohr-sensor I added a DHT to easily remove BME if the problem (with firmware-crashes) occurs "too often" and still have temp./humidity (even tough it's less precise).

At one of the sensors the BME values are often wrong, but at least the software don't get stuck, so the (important) measurements of PM and noise are still running.

Screenshot_20210118_043542

umweltsensor commented 3 years ago

Similar situation like @imaluschi's in my case. Have 3 Sensors, two of whitch are SDS011,BME280,DNMS one without DNMS. One Sensor runs very stable (esp8266-586719).

Following sensor (esp8266-7876127) goes south at some point. I can't identify the problem only some symptoms: image

BME280 07.01.2021 14:35:00 T:6 H:52% P:950 07.01.2021 14:45:00 T:-145 H:100% P:548

DNMS 07.01.2021 14:29:00 LAeq: 59.23 No next measure point, should have been at 14:39:00

BME280 stopps (Temp: -145°C; Humidity 100%; Pressure 548 HPa). DNMS stopped working too.