Real power #20

Open ghost opened 8 years ago

ghost commented 8 years ago

I am using Arduino mega, acs current sensor, step down transformer with bias (Only positive voltage cycle.) RMS value of current and voltage is accurate, apparent power also correct. Real power and thus power factor are inaccurate. There may be a circuit error but deviation is too large. Please help. Does the code have to be changed for acs current sensor ?

richard-scott commented 8 years ago

Can you provide a website link to the exact sensor you are using?

ghost commented 8 years ago

http://www.sunrom.com/p/current-sensor-20a-acs712

richard-scott commented 8 years ago

How are you connecting this to the AC supply you are measuring?

ghost commented 8 years ago

Using supply of ac mains. Supply-acs current sensor-choke-bulb-supply

Step down transformer parallel to load (choke + Bulb)

Aldair170496 commented 4 years ago

Hii! My objective is to read P, S, FP, Vrms and Irms. My currente calibration is 54.5 using a 33 burden resistor, SCT-013-000. I am using a 230/9 Vrms transformer, R1=120K e R2=10K, so the voltage calibration i use is 234.26 but the voltage values is stay less than 3V, why? Help me please!

CODE: { Serial.begin(9600);

emon1.voltage(2, 234.26, 1.7); // Voltage: input pin, calibration, phase_shift emon1.current(1, 54.5); // Current: input pin, calibration (2000/33). }

void loop() { emon1.calcVI(20,2000); // Calculate all. No.of half wavelengths (crossings), time-out emon1.serialprint(); // Print out all variables (realpower, apparent power, Vrms, Irms, power factor)

float realPower = emon1.realPower; //extract Real Power into variable float apparentPower = emon1.apparentPower; //extract Apparent Power into variable float powerFActor = emon1.powerFactor; //extract Power Factor into Variable float supplyVoltage = emon1.Vrms; //extract Vrms into Variable float Irms = emon1.Irms; //extract Irms into Variable delay(1000); }

Aldair170496 commented 4 years ago

Hi! I fix the problem, was in the hardware not in the software. But when the sensor or the voltage transformer are disconnected it should be all zero (0), how to fix that. Any help would be helpfull.

TrystanLea commented 4 years ago

Hello @Aldair170496, What kind of values do you see? can you give more detail?