Open socmonster opened 1 month ago
@Socmonster I think the default voltage levels on the JXADC pins is incorrect for use with a digital PMOD. JP6 on the genesys2 board selects the Voltage to be used on the JXDC PMOD. it should be jumpering pins 5 and 6 for 3.3v
Hi @gmartin102. Yes, I think the issue might be related to this case. I'm trying to debug it. When I change the JP6 jumper as you mentioned my HS2 connection fails. When JP6 jumper is on 1 and 2 for 1.8V, HS2 is working. I'll let you know if I can manage to solve the problem.
Is there an existing core-v-mcu bug for this?
Bug Description
Hello there,
I've been working on core-v-mcu for a little bit of time. I'm currently running cli_test on Genesys2 but I've did some work on Nexys as well. The problem between the two platform is that I cannot use PMOD SF3 on Genesys2. I can work on everything except of qspi flash commands. I've checked the JXADC pin connections, and they seem OK. I also tried to use another PMOD for flash connection, but the issue is still there. I don't think this is related to software stack as well. Is there anyone worked on Genesys2 and was able to boot from flash? I guess I'm in need of to be pointed into right direction. My clock speed configurations are like below.
SYS_CLK = 20 MHz PER_CLK = 5MHz
Kind regards,
socmonster