generator ordering considers tmux channel #227

Closed meeg closed 5 months ago

meeg commented 5 months ago

Generators are ordered by tProc output port. If the tProc mux is used, multiple generators will share a single tProc output, and they should be further ordered by the tmux output (previously they would keep their HWH ordering).