openrif / vivo-isf-ontology

The "VIVO-ISF Ontology" is an OWL2 representation of the VIVO-ISF Data Standard
16 stars 9 forks source link

Automated magnetic cell sorter #632

Closed isf-bot closed 9 years ago

isf-bot commented 9 years ago

From tjohn...@eagle-i.org on January 06, 2014 11:08:50

** Use the form below to request a new term * *** Scroll down to see a term request example *_ Please indicate the label for the proposed term: Automated magnetic cell sorter Please provide a textual definition (with source): A flow cytometer that uses the MACS method to allow cells to be separated by incubating with magnetic nanoparticles coated with antibodies against a particular surface antigen. (http://en.wikipedia.org/wiki/Magnetic-activated_cell_sorting) Note: not sure if we should use the MACS methos in the definition as it's a registered trademark of Miltenyi Biotec? Please add an example of usage for proposed term: http://www.miltenyibiotec.com/en/products-and-services/macs-cell-separation/automated-cell-separation/automacs-pro-separator.aspx Please provide any additional optional information below. (e.g. desired asserted SuperClass in ERO hierarchy or Reference Branch) Superclass: Flow cytometer sorter [ ] Instrument [ ] Biological process [ ] Disease [ ] Human studies [X] Instrument [ ] Organism [ ] Reagent [ ] Software [ ] Technique [ ] Organization Additional info: https://msm.eagle-i.net/sweet/#history?mode=view&instanceUri=http://msm.eagle-i.net/i/0000012f-a1ec-ff2f-df00-15fb80000000 _ Term request example **** Please indicate the label for the proposed term: four-terminal resistance sensor Please provide a textual definition (with source): "Four-terminal resistance sensors are electrical impedance measuring instruments that use separate pairs of current-carrying and voltage-sensing electrodes to make accurate measurements that can be used to compute a material's electrical resistance." http://en.wikipedia.org/wiki/Four-terminal_sensing Please add an example of usage for proposed term: Measuring the inherent (per square) resistance of doped silicon. Please provide any additional optional information below. (e.g. desired asserted SuperClass in ERO hierarchy or Reference Branch) [X] Instrument [ ] Biological process [ ] Disease [ ] Human studies [ ] Instrument [ ] Organism [ ] Reagent [ ] Software [ ] Technique [ ] Organization Additional info: AKA - 4T sensors, 4-wire sensor, or 4-point probe

Original issue: http://code.google.com/p/eagle-i/issues/detail?id=314

isf-bot commented 9 years ago

From vasil...@ohsu.edu on January 07, 2014 14:29:06

We already have cell separator, which is what the AutoMacs has been previously annotated to. Will that work?

isf-bot commented 9 years ago

From vasil...@ohsu.edu on January 07, 2014 14:44:45

added term 'automated magnetic cell separator'

Status: Fixed