openshwprojects / OpenBK7231T_App

Open source firmware (Tasmota/Esphome replacement) for BK7231T, BK7231N, BL2028N, T34, XR809, W800/W801, W600/W601 and BL602
https://openbekeniot.github.io/webapp/devicesList.html
1.35k stars 229 forks source link

QCB2-single phase smart circuit breaker #1139

Open alikarodi opened 3 months ago

alikarodi commented 3 months ago

Describe the bug is it possible to install openbeken on QCB2-single phase smart circuit breaker with mcu tuya wb3s? Thank you Firmware:

[ { "name": "QCB2-single phase smart circuit breaker", "id": "ff637fbefe67ffe3caaiuw", "key": "?????????????", "mac": "aa:80:56:1a:1c:06", "uuid": "9fa7779734b4ca2b", "sn": "10010011000316", "category": "dlq", "product_name": "QCB2-single phase smart circuit breaker", "product_id": "l1t5oophgyzpdrag", "biz_type": 18, "model": "", "sub": false, "icon": "https://images.tuyaeu.com/smart/icon/bay1638066107344ANbl/1853af3a98f2840a63ce3772edfde441.jpg", "mapping": { "1": { "code": "forward_energy_total", "type": "Integer", "values": { "unit": "kW\u00b7h", "min": 0, "max": 99999999, "scale": 2, "step": 1 } }, "6": { "code": "phase_a", "type": "Raw", "values": { "maxlen": 128 } }, "16": { "code": "switch", "type": "Boolean", "values": {} }, "102": { "code": "ov_set", "type": "Enum", "values": { "range": [ "Closed", "Alarm", "Trip" ] } }, "103": { "code": "uv_set", "type": "Enum", "values": { "range": [ "Closed", "Alarm", "Trip" ] } }, "104": { "code": "oc_set", "type": "Enum", "values": { "range": [ "Closed", "Alarm", "Trip" ] } }, "105": { "code": "op_set", "type": "Enum", "values": { "range": [ "Closed", "Alarm", "Trip" ] } }, "107": { "code": "temp_set", "type": "Enum", "values": { "range": [ "Closed", "Alarm", "Trip" ] } }, "109": { "code": "online_state", "type": "Enum", "values": { "range": [ "online", "offline" ] } }, "110": { "code": "event", "type": "Enum", "values": { "range": [ "Normal", "Over_Current_Trip", "Over_Power_Trip", "High_Temp_Trip", "Over_Voltage_Trip", "Under_Voltage_Trip", "Over_Current_Alarm", "Over_Power_Alarm", "High_Temp_Alarm", "Over_Voltage_Alarm", "Under_Voltage_Alarm", "Remote_ON", "Remote_OFF", "Manual_ON", "Manual_OFF", "Leakage_Trip", "Leakage_Alarm", "Restore_Default", "Automatic_Closing", "Electricity_Shortage", "Electricity_Shortage_Alarm" ] } }, "112": { "code": "auto_reclosing", "type": "Boolean", "values": {} }, "114": { "code": "c_thresh", "type": "Integer", "values": { "unit": "A", "min": 1, "max": 63, "scale": 0, "step": 1 } }, "115": { "code": "ov_thresh", "type": "Integer", "values": { "unit": "V", "min": 245, "max": 295, "scale": 0, "step": 1 } }, "116": { "code": "uv_thresh", "type": "Integer", "values": { "unit": "V", "min": 145, "max": 220, "scale": 0, "step": 1 } }, "118": { "code": "temp_thresh", "type": "Integer", "values": { "unit": "\u00b0C", "min": -250, "max": 1000, "scale": 1, "step": 1 } }, "119": { "code": "op_thresh", "type": "Integer", "values": { "unit": "W", "min": 5, "max": 25000, "scale": 0, "step": 10 } }, "125": { "code": "fap_a", "type": "Integer", "values": { "unit": "kW\u00b7h", "min": -999999999, "max": 999999999, "scale": 2, "step": 1 } }, "131": { "code": "temp_a", "type": "Integer", "values": { "unit": "\u00b0C", "min": -250, "max": 1000, "scale": 1, "step": 1 } }, "113": { "code": "rd_set", "type": "Boolean", "values": {} } } }

To Reproduce Steps to reproduce the behavior:

  1. Go to '...'
  2. Click on '....'
  3. Scroll down to '....'
  4. See error

Screenshots If applicable, add screenshots to help explain your problem.

Additional context Add any other context about the problem here.

openshwprojects commented 3 months ago

Sure, I can guide you step by step through the process on our forum. SEe also tutorial: https://www.elektroda.com/rtvforum/viewtopic.php?p=20975937#20975937