Closed bbuenim closed 2 years ago
Hello.
Please: 1) Attach input cif (rename it to txt). 2) Add supercell program output as code block (check markdown syntax). 3) Try to make your request more transparent. Add some details.
A far as I understand now: 1) For such system charge should not be an issue, whenever Ge and Si have the same charge. 2) 16Si + 16Ge is a very simple task for supercell. You can get the result in less than one minute even in your laptop machine.
Hi
Sorrry for inconvenience.
I attached the input file as txt form(cif file) Si2O3.txt
Here I would like to change 32 Si into 16 Si and 16 Ge based on charges and get 20 stcutures from the lowest.
and command to run is "supercell -i Si2O3.cif -s 1x1x1 -m -o 1_50/POSCAR "
but result is like below: The initial was looks good But, my scrren just stops like below and does not go to the next
Please confirm this situation.
Thanks for your help.
Supercell program search for symmetry by labels. So you should have for the same site the same label. Something like this for Si (for Ge also):
Si1 0.5 0.25 0.217318 0.5 Uiso ? Si
Si1 0.5 0.282682 0.5 0.75 Uiso ? Si
Si1 0.5 0.5 0.25 0.217318 Uiso ? Si
Si1 0.5 0.217318 0.5 0.25 Uiso ? Si
Si1 0.5 0.5 0.75 0.282682 Uiso ? Si
Si12 0.5 0.75 0.217318 0 Uiso ? Si
Thanks fot your reply.
But , In my case, labe occ x y z Si1 0.5 0.25 0.217318 0.5 Uiso ? Si Si1 0.5 0.282682 0.5 0.75 Uiso ? Si Si1 0.5 0.5 0.25 0.217318 Uiso ? Si Si1 0.5 0.217318 0.5 0.25 Uiso ? Si Si1 0.5 0.5 0.75 0.282682 Uiso ? Si
these 5 Si have different site as you can x,y,z (fractional coordinate)
Why do you make 5 Si into same label like Si1 from my data ? so sorry, I don't understand why do you think the 5 Si should have same label.
Could you please tell me why?
Thanks for your help
Sorry for repeating, but "Supercell program search for symmetry by labels. So you should have for the same site the same label." This 5 Si was only an example. You should check by your self sites and symmetries. Please check the group concept in my paper https://jcheminf.biomedcentral.com/articles/10.1186/s13321-016-0129-3#Sec5 and the tutorial: https://orex.github.io/supercell/doc/supercell_tutorial.pdf
Thanks for your explanations.
I will looked more your links
Thanks
Hi
I have a question.
I would like to mix element by keeping the cell size. just mix the initial element with the other element
EX.) SiO2
There are 8 Si and 16 O.
8 Si -> 4 Si and 4 Ge So, i prepared the file cif
if I expand cell (e.g. -s 2x1x1 ) is fine to make cell. but -s 1x1x1 case just give only 1 configuration.
but, There are 8C4= 70 cases
And Although I add charge for each element and consider those charges , it does also give 1 configuration.
Q1. Is it difficult to calculate the intermixing like this case for 1x1x1 in the large unit cell( total number of atoms > 80 , here 32 SI -> 16 Si and 16 Ge)
Thanks