Closed gullbrekken closed 3 months ago
I could add that the second coefficient is also positive (5.65) in the EMIM.itp file.
Thank you for catching this typo. The value should be negative as reported in the papers (and as listed for BMIM and OMIM). I have updated both EMIM files.
Thank you!
In the EMIM_scale0.8.itp file the CW-NA-CA-HA dihedral has coefficients V1 to V4: -2.7 5.65 0.355 0. See line 140 in the file. However, in the original paper "Development of OPLS-AA Force Field Parameters for 68 Unique Ionic Liquids" and in the SI of "Revisiting OPLS Force Field Parameters for Ionic Liquid Simulations", the coefficients for this dihedral are: -2.700 -5.650 0.355. So the second coefficient is negative, while it is positive in the ITP file. I want to simulate a system containing EMIM, so my question is, which value is correct?