Open attiliocn opened 9 months ago
It seems that my code breaks the functionality for Gaussian outputs! Working on that.
-- Ok, this break seems to be happening when an G16 output and ORCA 5.0.4 outputs are in the same directory with the same base name (water.log and water.out for example)
I have written a parser for Orca 5.0.4 thermochemistry data (thermo.py file) based on the implementation available for the NWChem. I didn't fully understand the symmetry portion of the code, so I let this part half-implemented (Recover the symmetry number and point group from the output, but I didn't assign a value to
symno
orlinear_mol
.) . Also, I didn't find a "Rotational temperature" in the Orca output, as it is available in Gaussian 16 calculations. With some help, I can finish this implementation and fully test it. Also, I use a loop per property. This is somewhat different from the current implementation (a single loop and parsing the properties as you go) and I have employed regular expressions too. If necessary, I can refactor this code to comply with the structure used in Gaussian and NWChem parsers.