spaulaus commented 9 years ago

I found this error log on grpc02 under the pixie16 account. We had an error on September 28, 2015. I believe we were first starting to do the test setup for the VANDLE setup at ISOLDE to produce high rate related issues. I do not think that we saw the message again after the slot read error was fixed.

The error message is as follows

POLL2 $ startacq
Starting list mode run............................[OK]
Acq started on Mon Sep 28 15:05:39 2015
POLL2 $ stopacq
Ending run........................................[OK]
Run end status in module 0........................[OK]
Run end status in module 1........................[OK]
Acq stopped on Mon Sep 28 15:05:49 2015
POLL2 $ startacq
Starting list mode run............................[OK]
Acq started on Mon Sep 28 15:05:53 2015
[ERROR] Not enough words available in module 1's FIFO for read! (0/47778)
[ERROR] Unable to read 47778 from module 1
Ending run........................................[OK]
Run end status in module 0........................[OK]
Run end status in module 1........................[OK]
Acq stopped on Mon Sep 28 15:05:53 2015
ksmith0 commented 8 years ago

As this has not been reproduced, I'm closing it until it is observed again.