poldracklab / pydeface

defacing utility for MRI images
MIT License
112 stars 42 forks source link

Blurring instead of zeroing #7

Open chrisgorgo opened 7 years ago

chrisgorgo commented 7 years ago

For MEG usecase strict masking is interfering with skull surface reconstructions. It is recommended to blur the face instead. This could be easily achieved using https://afni.nimh.nih.gov/pub/dist/doc/program_help/3dBlurToFWHM.html