Closed GoogleCodeExporter closed 9 years ago
I couldn't find any mention of the Tetrix controller on HiTechnic's product
page. Could you please link to more information about it?
Original comment by marcus@wanners.net
on 23 Nov 2010 at 8:47
Hi
I have few referneces to the Tetrix DC and servo controllers for the Tetrix
http://www.robotc.net
http://www.tetrixrobotics.com/MINDSTORMS_Controlled/Downloads/default.aspx?aid=8
4
http://www.legoeducation.us/store/detail.aspx?ID=1648&bhcp=1
http://www.legoeducation.us/store/detail.aspx?CategoryID=187&by=9&ID=1649&c=1&t=
0&l=0
Original comment by henrya...@hotmail.com
on 24 Nov 2010 at 12:47
Ah, now I know what you're talking about. I checked out those references and
couldn't find any protocol docs for the device. Do you know whether it plugs
into a motor port or a sensor port? If it's a sensor port thing, you'll need to
find the I2C protocol docs for it. Once I have those, I can create a patch and
send it to you for testing.
Thanks!
Original comment by marcus@wanners.net
on 24 Nov 2010 at 7:39
Alternatively, an NXC program or library which uses it would work as
well...those are usually pretty easy to reverse-engineer.
Original comment by marcus@wanners.net
on 24 Nov 2010 at 7:40
Are you still interested in this? I will need the requested docs to continue.
If there is no response in the next few days, I will close this issue.
Original comment by marcus@wanners.net
on 3 Jan 2011 at 7:32
Hi Sorry for the delay, as the files where a bit hard to get but Hitechnic has
provided them,
Thanks
Original comment by henrya...@hotmail.com
on 4 Jan 2011 at 1:24
Attachments:
Thanks. I will work on implementing this. In the mean time, it would be most
helpful if you could provide me with the output of a get_sensor_info() call on
a BaseDigitalSensor object controlling the sensor. If you don't know what I'm
talking about I can probably get you some example code.
Original comment by marcus@wanners.net
on 4 Jan 2011 at 3:08
well if you don't mind sending me the code I will need to rus as I'm just
starting to learn Python
:)
Thanks
Original comment by henrya...@hotmail.com
on 4 Jan 2011 at 4:55
import nxt
b = nxt.find_one_brick()
s = nxt.BaseDigitalSensor(b, nxt.PORT_1)
print s.get_sensor_info()
With the sensor attached to port 1.
Original comment by marcus@wanners.net
on 4 Jan 2011 at 5:03
Hi I have this output, not sure but seems that I have something wrong in my
installation
I have the DC motor controlled attached to port 1 and the NXT brick on the usb
import nxt
>>> b = nxt.find_one_brick()
>>> s = nxt.BaseDigitalSensor(b, nxt.PORT_1)
>>> print s.get_sensor_info()
Traceback (most recent call last):
File "<stdin>", line 1, in <module>
File "nxt/sensor/digital.py", line 140, in get_sensor_info
version = self.read_value('version')[0].split('\0')[0]
File "nxt/sensor/digital.py", line 127, in read_value
return self._i2c_query(address, fmt)
File "nxt/sensor/digital.py", line 112, in _i2c_query
self._ls_get_status(n_bytes)
File "nxt/sensor/digital.py", line 85, in _ls_get_status
b = self.brick.ls_get_status(self.port)
File "nxt/brick.py", line 26, in poll
return parse_func(igram)
File "nxt/direct.py", line 149, in _parse_ls_get_status
tgram.check_status()
File "nxt/telegram.py", line 112, in check_status
nxt.error.check_status(self.parse_u8())
File "nxt/error.py", line 85, in check_status
raise ex
nxt.error.DirProtError: Communication bus error
Original comment by henrya...@hotmail.com
on 9 Jan 2011 at 4:59
and this is output with the servo controller at port 1 on the nxt
print s.get_sensor_info()
Traceback (most recent call last):
File "<stdin>", line 1, in <module>
File "nxt/sensor/digital.py", line 140, in get_sensor_info
version = self.read_value('version')[0].split('\0')[0]
File "nxt/sensor/digital.py", line 127, in read_value
return self._i2c_query(address, fmt)
File "nxt/sensor/digital.py", line 111, in _i2c_query
self.brick.ls_write(self.port, msg, n_bytes)
File "nxt/brick.py", line 24, in poll
self.sock.send(str(ogram))
File "nxt/usbsock.py", line 65, in send
self.handle.bulkWrite(self.blk_out.address, data)
usb.USBError: error submitting URB: No such device
Original comment by henrya...@hotmail.com
on 9 Jan 2011 at 5:01
[deleted comment]
with the DC motor controller connected in port 1
>>> import nxt
>>> b = nxt.find_one_brick()
>>> s = nxt.BaseDigitalSensor(b, nxt.PORT_1)
>>> print s.get_sensor_info()
Version: `�V2.0 `
0xfd, 0x56, 0x32, 0x2e, 0x30, 0x20, 0x20, 0x20,
Product ID: `HiTechnc`
0x48, 0x69, 0x54, 0x65, 0x63, 0x68, 0x6e, 0x63,
Type: `MotorCon`
0x4d, 0x6f, 0x74, 0x6f, 0x72, 0x43, 0x6f, 0x6e,
and with the servo controller i got
>>> import nxt
>>> b = nxt.find_one_brick()
>>> s = nxt.BaseDigitalSensor(b, nxt.PORT_1)
>>> print s.get_sensor_info()
Version: `�V1.4 `
0xfd, 0x56, 0x31, 0x2e, 0x34, 0x20, 0x20, 0x20,
Product ID: `HiTechnc`
0x48, 0x69, 0x54, 0x65, 0x63, 0x68, 0x6e, 0x63,
Type: `ServoCon`
0x53, 0x65, 0x72, 0x76, 0x6f, 0x43, 0x6f, 0x6e,
Original comment by henrya...@hotmail.com
on 9 Jan 2011 at 5:13
[deleted comment]
OK, I will ask them if they can provide me with the most recent spec
Thanks
Original comment by henrya...@hotmail.com
on 9 Jan 2011 at 6:12
[deleted comment]
[deleted comment]
[deleted comment]
Hi
I've been told that the document is the latest version and the version number
of the document does not correspond to the firmware version.
Which is a good news :)
one thing, could you please let me know how can I patch it, and do you mind
send me some testing code to test the encoders
Thanks :)
Original comment by henrya...@hotmail.com
on 13 Jan 2011 at 4:38
If you're on windows, would use TortoiseSVN's Patch feature. If you're on
linux, you use the patch command. The syntax is tricky, google can help. As for
code, I'm not sure exactly how one would use the motors. Look at the other
sensor examples and the comments in the patch to see how the syntax should go.
If you can post your testing code, I will add it as an example.
Original comment by marcus@wanners.net
on 14 Jan 2011 at 3:20
[deleted comment]
I have applied the patch and then I did reinstall nxt-python
when building I got this error
running install_lib
copying build/lib.linux-i686-2.6/nxt/sensor/hitechnic.py ->
/usr/local/lib/python2.6/dist-packages/nxt/sensor
byte-compiling /usr/local/lib/python2.6/dist-packages/nxt/sensor/hitechnic.py
to hitechnic.pyc
SyntaxError: ('invalid syntax',
('/usr/local/lib/python2.6/dist-packages/nxt/sensor/hitechnic.py', 567, 7, '
def get_pid(self, mot):\n'))
could you please advice
Thanks
Original comment by henrya...@hotmail.com
on 18 Jan 2011 at 9:15
[deleted comment]
Running into problems here with the Communication bus error.
I have run the code
>>> import nxt
>>> b = nxt.find_one_brick()
>>> s = nxt.BaseDigitalSensor(b, nxt.PORT_1)
>>> print s.get_sensor_info()
on two different machines with no success. My error is:
Traceback (most recent call last):
File "<stdin>", line 1, in <module>
File "/usr/local/lib/python2.6/dist-packages/nxt/sensor/digital.py", line 140, in get_sensor_info
version = self.read_value('version')[0].split('\0')[0]
File "/usr/local/lib/python2.6/dist-packages/nxt/sensor/digital.py", line 127, in read_value
return self._i2c_query(address, fmt)
File "/usr/local/lib/python2.6/dist-packages/nxt/sensor/digital.py", line 112, in _i2c_query
self._ls_get_status(n_bytes)
File "/usr/local/lib/python2.6/dist-packages/nxt/sensor/digital.py", line 85, in _ls_get_status
b = self.brick.ls_get_status(self.port)
File "/usr/local/lib/python2.6/dist-packages/nxt/brick.py", line 26, in poll
return parse_func(igram)
File "/usr/local/lib/python2.6/dist-packages/nxt/direct.py", line 149, in _parse_ls_get_status
tgram.check_status()
File "/usr/local/lib/python2.6/dist-packages/nxt/telegram.py", line 112, in check_status
nxt.error.check_status(self.parse_u8())
File "/usr/local/lib/python2.6/dist-packages/nxt/error.py", line 85, in check_status
raise ex
nxt.error.DirProtError: Communication bus error
Any advice? Simply running the last command twice does not appear to be a
viable solution as suggested.
Original comment by forrest....@gmail.com
on 18 Jan 2011 at 10:46
henry:
That's exactly the error I'm looking for, and good job patching the source!
I'll have an updated patch for you to test as soon as I can. Thanks.
fmc:
I don't know what causes this error, but for me it only happens occasionally.
Could you test with a v1.x release and with the 0.7 NXT_Python package please?
The method for get_sensor_info() may be different or nonexistant on some of
these, just try reading a value if you can't do that specific one.
Original comment by marcus@wanners.net
on 19 Jan 2011 at 2:01
Here's the updated patch file. Sorry about that, simple missing parentheses. My
bad; probably should have at least parsed the code before sending it.
Original comment by marcus@wanners.net
on 19 Jan 2011 at 2:32
Attachments:
:) the patch has been successfully applied.
could you please advice which simple code can I use to test them
Thanks
Original comment by henrya...@hotmail.com
on 19 Jan 2011 at 8:32
Here is a recent log from ipython (this is the same error as before, but with a
traceback):
In [1]: import nxt
In [2]: b = nxt.find_one_brick()
In [3]: s = nxt.Base
nxt.BaseAnalogSensor nxt.BaseDigitalSensor nxt.BaseMotor
In [3]: s = nxt.BaseDigitalSensor(b, nxt.PORT_4)
In [4]: s.get_sensor_info()
---------------------------------------------------------------------------
DirProtError Traceback (most recent call last)
/usr/local/lib/python2.6/dist-packages/nxt/sensor/digital.py in
get_sensor_info(self)
138
139 def get_sensor_info(self):
--> 140 version = self.read_value('version')[0].split('\0')[0]
141 product_id = self.read_value('product_id')[0].split('\0')[0]
142 sensor_type = self.read_value('sensor_type')[0].split('\0')[0]
/usr/local/lib/python2.6/dist-packages/nxt/sensor/digital.py in
read_value(self, name)
125 """
126 address, fmt = self.I2C_ADDRESS[name]
--> 127 return self._i2c_query(address, fmt)
128
129 def write_value(self, name, value):
/usr/local/lib/python2.6/dist-packages/nxt/sensor/digital.py in
_i2c_query(self, address, format)
110 sleep(0.02 - diff)
111 self.brick.ls_write(self.port, msg, n_bytes)
--> 112 self._ls_get_status(n_bytes)
113 data = self.brick.ls_read(self.port)
114 self.lastpoll = time()
/usr/local/lib/python2.6/dist-packages/nxt/sensor/digital.py in
_ls_get_status(self, n_bytes)
83 for n in range(3):
84 try:
---> 85 b = self.brick.ls_get_status(self.port)
86 if b >= n_bytes:
87 return b
/usr/local/lib/python2.6/dist-packages/nxt/brick.pyc in poll(self, *args,
**kwargs)
24 self.sock.send(str(ogram))
25 igram = Telegram(opcode=opcode, pkt=self.sock.recv())
---> 26 return parse_func(igram)
27 return poll
28
/usr/local/lib/python2.6/dist-packages/nxt/direct.pyc in
_parse_ls_get_status(tgram)
147
148 def _parse_ls_get_status(tgram):
--> 149 tgram.check_status()
150 n_bytes = tgram.parse_u8()
151 return n_bytes
/usr/local/lib/python2.6/dist-packages/nxt/telegram.pyc in check_status(self)
110
111 def check_status(self):
--> 112 nxt.error.check_status(self.parse_u8())
113
114 import nxt.direct
/usr/local/lib/python2.6/dist-packages/nxt/error.pyc in check_status(status)
83 ex = CODES.get(status)
84 if ex:
---> 85 raise ex
86 else:
87 raise ProtocolError, status
DirProtError: Communication bus error
____________________________________________________________-
I am, however, able to communicate with a touch sensor I have connected in
PORT_1 by the small script:
#!/usr/bin/env python
import nxt
b = nxt.find_one_brick()
t = nxt.Touch(b, nxt.PORT_1)
print t.get_sample() #'TRUE' or 'FALSE' depending on touch state
# end script
I could also communicate with the touch sensor in a similar way in version 1.2
through this script:
#!/usr/bin/env python
import time
import nxt.locator
from nxt.sensor import *
sock = nxt.locator.find_one_brick()
if sock:
b = test_sensors(sock.connect())
t = TouchSensor(b, PORT_1)
print t.get_sample()
sock.close()
else:
print 'No NXT bricks found'
# end script
I could find no similar method call like get_sensor_info() in 1.2. I have not
looked at version .7, but I'm not sure that is relevant.
Also, some more information, maybe it's helpful
In [1]: import nxt
In [2]: b = nxt.find_one_brick()
In [3]: b.get_device_info()
Out[3]:
('NXT\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00',
'00:16:53:0C:02:FF',
0,
82516)
In [4]: b.get_firmware_version()
Out[4]: ((1, 124), (1, 28))
Still, I cannot solve the Communication bus error.
Original comment by forrest....@gmail.com
on 20 Jan 2011 at 9:52
Protocol error guy: This seems to be a problem with some optimization code we
implemented a while back. It was designed to reduce effect of bt/usb latency on
the performance of nxt-python. Please open a new ticket with details on the
versions you see this problem with. In the mean time, you can try tweaking the
value in lines 108 and 110 of sensor/digital.py and seeing if that fixes it.
The one chosen was thought to be conservative and worked in most cases, but it
may not be working with your configuration. This can be easily fixed with your
cooperation, and thanks for that neat traceback format.
Need examples guy: That's really dependent on how the sensor is meant to be
used. In general, apply the patch, install the package (you seem to have got
this right) and then do something like this:
#with a brick as b
from nxt.sensor import *
from nxt.sensor.hitechnic import ServoCon, MotorCon #needed because the aliases
aren't set up in sensor/__init__.py yet
cur = mot.get_enc_current(1)
print cur #should be 0 if the motor hasn't moved since being powered on
mot.set_encoder_target(cur+360) #should move the motor one rotation...
mot.set_power(70) #...at 70% power
at this point, you can do a print dir(mot) to see what other methods are
available. check out the comments in the patch to see how to use them
srv = ServoCon(b, PORT_2)
print srv.get_status() #should be 0
srv.set_pos(1, 60) #set servo 1 to position 60
print srv.get_status() #should be 1
while srv.get_status() != 0:
print "running..." #print running... as long as the motor is moving
print "stopped." #should print stopped as soon as the motor isn't moving anymore
again, play with the other methods and report any weird stuff. I will warn you
that set_get_ratio on motors isn't implemented yet by HiTechnic, so it won't
work.
Thanks!
Original comment by marcus@wanners.net
on 20 Jan 2011 at 10:27
Alright, reporting back here, still having issues.
I took a look at lines 108 and 110 in digital.py and my first attempt was too
change the two occurrences of value .02 to something greater like you
suggested. I tried values like .04, .08 and then eventually something huge like
5. Nothing worked. I then realized that in the step-by-step debugger things
were screwy because I was taking excessive time between time() calls while
stepping, so I modified the code further...
Here are my changes:
def _i2c_query(self, address, format):
"""Reads an i2c value from given address, and returns a value unpacked
according to the given format. Format is the same as in the struct
module. See http://docs.python.org/library/struct.html#format-strings
"""
n_bytes = struct.calcsize(format)
msg = chr(self.I2C_DEV) + chr(address)
t = time()
if not self.lastpoll: self.lastpoll = t
#import pdb; pdb.set_trace()
if self.lastpoll+5 > t:
diff = t - self.lastpoll
sleep(4 - diff)
self.brick.ls_write(self.port, msg, n_bytes)
self._ls_get_status(n_bytes)
data = self.brick.ls_read(self.port)
self.lastpoll = t
if len(data) < n_bytes:
raise I2CError, 'Read failure'
return struct.unpack(format, data[-n_bytes:]) # TODO: why could there be more than
This basically involves setting t to time() near the top and using this same
value throughout the function call.
Anyways, I'm still getting the communication bus error. One thing to note
however, the first time I run
"import nxt
b = nxt.find_one_brick()
s = nxt.BaseDigitalSensor(b, nxt.PORT_4)
s.get_sensor_info()"
the code posted DOES enter the if statement at line 110 and sleeps for some
amount of time, eventually resulting in the error. Subsequent calls to
s.get_sensor_info() result in the error immediately without sleeping. If I
re-initialize s by saying s = nxt.BaseDigitalSensor(b, nxt.PORT_4) again and
then call s.get_sensor_info(), the code will sleep again, but subsequent calls
to s.get_sensor_info() error immediately.
Not sure what to do at this point.
Any more suggestions?
Thanks!
Original comment by forrest....@gmail.com
on 25 Jan 2011 at 6:51
I will take a good look at that code as soon as I get a bit of time with my dev
box. In the mean time, are you using USB or bluetooth? Does switching from one
to the other change things at all?
As I said, if you wouldn't mind, start a new issue for this as it's obviously
separate from the one this issue is about.
Original comment by marcus@wanners.net
on 25 Jan 2011 at 9:05
All right. I can't reproduce your error and actually haven't gotten ANY errors
at all using either USB or Bluetooth (with the latest SVN). If you can't find a
way to fix the issue, please open a new issue which details exactly what you're
doing including:
OS
Python version
NXT hardware/software/protocol version numbers
NXT-python release version number or SVN revision
USB or BT? (test with both if possible)
PyUSB/pybluez version number
Until I have this information, I'm really at a loss as far as what's going on
here. If you're on Ubuntu, you can use wireshark to watch exactly what's going
on with the USB ports in real time. Might help with debugging.
Sorry I couldn't figure out why this is happening to you.
Original comment by marcus@wanners.net
on 27 Jan 2011 at 9:27
Any word from the OP on this?
Original comment by marcus@wanners.net
on 1 Feb 2011 at 10:17
I'm going to add this code but mark it as untested. If you test it at some
point, let me know how things go.
Original comment by marcus@wanners.net
on 6 Feb 2011 at 1:18
http://www.education.rec.ri.cmu.edu/products/getting_started_tetrix/nxtg/softwar
e/software_index.html
Original comment by humberto...@gmail.com
on 20 Nov 2014 at 3:35
Original issue reported on code.google.com by