post-kerbin-mining-corporation / DynamicBatteryStorage

Resolves issues with electrical power handling in Kerbal Space Program and provides user interface planning tools for heat and electrical generation.
17 stars 12 forks source link

Power Flow not visible with Kopernicus 1.9.1-1 (CKAN Release) #67

Closed hemeac closed 4 years ago

hemeac commented 4 years ago

As Kopernicus changes the ModuleDeployableSolarPanel to KopernicusSolarPanels, that makes all solar panels hidden in the Systems Manager UI. Within DynamicBatteryStorageSettings.cfg, you have a KopernicusSolarPanel in Handlercategory which doesn't catch the name of the current module, but adding module = KopernicusSolarPanels as well as the related partmodulehandler appears to fix the issue.

ChrisAdderley commented 4 years ago

Released with 2.1.9