precision-sustainable-ag / Hotline-Issues

Current protocols for the on-farm trial network
MIT License
1 stars 0 forks source link

Water Sensors: OFP Indigo Brooke #321

Closed kldriver closed 1 year ago

kldriver commented 1 year ago

R1B: Never made an initial connection (589) R1C: middle is reading 0, surface and deep appear to be struggling to pick an algorithm, no top sensor reading R2B: top is reading 0, middle and deep are having a little trouble choosing and algorithm R2C: Deep is reading very close to zero, and the middle sensor is struggling to choose an algorithm.

elhenriq commented 1 year ago

most likely solution is to do a re install on the entire set! or make sure all sensors are properly seated! these are the updated TDR's they should not be reading with multiple formulas.

kldriver commented 1 year ago

Emailed 6/1.

kldriver commented 1 year ago

Surface temp reading -999/99

kldriver commented 1 year ago

deep sensor not sending data

elhenriq commented 1 year ago

R1C: c (deep) sensor is not working, check cable and check for rocks. maybe need a replacement sensor R1B: a (top) sensor is not working, check cable and check for rocks. maybe need a replacement sensor

kldriver commented 1 year ago

Issue persists, poking Brooke today.

kldriver commented 1 year ago

Poking today.

elhenriq commented 1 year ago

rep 1 bare is top sensor is still not working, rep one cover stop comunicating yesterday also need to check deep sensor

kldriver commented 1 year ago

Data now present.