Water Sensors: Temperature sensors #358

Open kldriver opened 1 year ago

kldriver commented 1 year ago
-41 C >real C Temp if >real C
FSX GWP 43
INN MGT 614.36
21000251 TSH 614.36
HAP 280920 53.46
ZFW NYC 614.36
TDI ZEE 48.05
DKP ZTP 614.36
HGU    
     

elhenriq commented 1 year ago

all those need to be replace with new Temp sensors.

saseehav commented 1 year ago

@elhenriq all 15 sites shipped new Temp sensors for litter bags? Close if true

elhenriq commented 1 year ago

i have not. will be sending this week or monday latest.

brianwdavis commented 1 year ago

Over the last 3 years, this is how many rows have -41 for the temperature of TDR probes by year, depth, and sensor ID

count yr node_serial_no tdr_address tdr_sensor_id
5 2021.0 18000243 2 14Acclima TR315H2.790071917
1 2021.0 18000593 b 14Acclima TR310H2.314007804
4193 2022.0 18000455 A 14Acclima TR310H2.314007958
2430 2022.0 18000591 A 14Acclima TR310H2.314007954
43 2022.0 18000684 B 14Acclima TR310H2.314007832
146 2022.0 18001806 B 14Acclima TR310H2.314007819
1 2022.0 18000470 c 14Acclima TR310H2.314007584
718 2022.0 18000665 c 14Acclima TR310H2.314007916
5513 2022.0 18000333 C 14Acclima TR310H2.314007928
2376 2022.0 18001783 d 14Acclima TR310S4.314002731
2499 2023.0 18000544 a 14Acclima TR310H2.314007926
174 2023.0 18001811 a 14Acclima TR310H2.314007892
102 2023.0 18000447 A 14Acclima TR310H2.314007954
2103 2023.0 18000491 A 14Acclima TR310H2.314007958
4090 2023.0 18001865 A 14Acclima TR310H2.414008170
2800 2023.0 18001790 b 14Acclima TR310H2.414008151
3065 2023.0 18000333 B 14Acclima TR310H2.314007819
2821 2023.0 18000446 B 14Acclima TR310H2.314008027
594 2023.0 18000361 c 14Acclima TR310H2.614007832
206 2023.0 18000375 C 14Acclima TR310H2.314007928
325 2023.0 18000578 C 14Acclima TR310H1.014005785
2 2023.0 18000600 C 14Acclima TR310H2.314007776
1906 2023.0 18001785 C 14Acclima TR310H2.314008743
4111 2023.0 18001865 C 14Acclima TR310H2.314007839
brianwdavis commented 1 year ago

Over the last 3 years, this is how many rows have -41 for the litter bag temperature sensors by year and sensor ID

count yr node_serial_no temp_sensor_id
4690 2021.0 18000018 14Acclima Temp010.334000049
3001 2021.0 18000379 14Acclima Temp010.334000047
3421 2021.0 18000380 14Acclima Temp010.334000069
2252 2021.0 18000386 14Acclima Temp010.334000025
9231 2021.0 18000418 14Acclima Temp010.334000030
275 2021.0 18000432 14Acclima Temp010.334000029
8684 2021.0 18000453 14Acclima Temp010.334000029
4006 2021.0 18000466 14Acclima Temp010.334000032
3164 2021.0 18000518 14Acclima Temp010.334000049
11 2021.0 18000525 14Acclima Temp010.334000051
493 2021.0 18000527 14Acclima Temp010.334000046
6179 2021.0 18000534 14Acclima Temp010.334000017
9663 2021.0 18000537 14Acclima Temp010.334000051
12941 2021.0 18000630 14Acclima Temp010.334000041
969 2022.0 18000320 14Acclima Temp010.334000030
5074 2022.0 18000337 14Acclima Temp010.334000034
333 2022.0 18000372 14Acclima Temp010.334000073
2 2022.0 18000409 14Acclima Temp010.334000021
11881 2022.0 18000421 14Acclima Temp010.334000017
1 2022.0 18000446 14Acclima Temp010.334000029
8253 2022.0 18000456 14Acclima Temp010.334000029
2442 2022.0 18000456 14Acclima Temp010.334000034
10958 2022.0 18000465 14Acclima Temp010.334000066
1 2022.0 18000465 14Acclima Temp010.334000069
3708 2022.0 18000491 14Acclima Temp010.334000162
335 2022.0 18000510 14Acclima Temp010.334000049
1 2022.0 18000517 14Acclima Temp010.334000034
9042 2022.0 18000534 14Acclima Temp010.334000021
13615 2022.0 18000536 14Acclima Temp010.334000046
3493 2022.0 18000555 14Acclima Temp010.334000047
3297 2022.0 18000616 14Acclima Temp010.334000051
117 2022.0 18000636 14Acclima Temp010.334000069
1 2022.0 18000642 14Acclima Temp010.334000047
7504 2022.0 18000654 14Acclima Temp010.334000026
1268 2022.0 18000688 14Acclima Temp010.334000153
3073 2022.0 18000701 14Acclima Temp010.334000115
6 2022.0 18001787 14Acclima Temp010.334000047
1 2022.0 18001811 14Acclima Temp010.334000047
6774 2022.0 18001825 14Acclima Temp010.334000157
8033 2022.0 18001841 14Acclima Temp010.334000064
8902 2022.0 18001846 14Acclima Temp010.334000032
7157 2022.0 18001854 14Acclima Temp010.334000025
4610 2023.0 18000341 14Acclima Temp010.334000026
2610 2023.0 18000342 14Acclima Temp010.334000153
2099 2023.0 18000359 14Acclima Temp010.334000162
2680 2023.0 18000365 14Acclima Temp010.334000064
121 2023.0 18000400 14Acclima Temp010.334000126
20 2023.0 18000409 14Acclima Temp010.334000039
644 2023.0 18000420 14Acclima Temp010.334000058
593 2023.0 18000425 14Acclima Temp010.334000157
4 2023.0 18000455 14Acclima Temp010.334000162
49 2023.0 18000457 14Acclima Temp010.334000017
1399 2023.0 18000497 14Acclima Temp010.334000030
2496 2023.0 18000501 14Acclima Temp010.334000073
2 2023.0 18000541 14Acclima Temp010.334000017
110 2023.0 18000566 14Acclima Temp010.334000069
151 2023.0 18000638 14Acclima Temp010.334000100
94 2023.0 18000665 14Acclima Temp010.334000106
1497 2023.0 18000696 14Acclima Temp010.334000051
490 2023.0 18000716 14Acclima Temp010.334000046
4260 2023.0 18001791 14Acclima Temp010.334000066
kldriver commented 1 year ago

Matching sheet

https://docs.google.com/spreadsheets/d/1I0ZtFCRieCEnMzTH2B7G0kODhooNC90Ha6DoAdkYqd8/edit#gid=0

elhenriq commented 1 year ago

all sensors been shipped today.

elhenriq commented 1 year ago

additional farms with temp (litter bag) sensors issues:

RVP MGT TOI

kldriver commented 1 year ago

Per Chris: If the TDR soil temperature is giving -41 error but TDR VWC looks okay, leave the TDR alone. Don't disturb and replace. We would rather throw out the soil temp than disturb the TDR.

elhenriq commented 1 year ago

i have already sent all the replacement TDR's some people have already started replacing them.

kldriver commented 1 month ago

@brianwdavis Any next steps for this issue? Can we close?