Closed elhenriq closed 3 months ago
Site is completely offline. Rep 2 Cover middle sensor went off before the whole site.
Charles replaced two of these nodes a little bit ago, all the nodes are working fine, but it is not reflected on the charts since hi has not submitted the form (I don't think).
Looks like he submitted a install form on June 29th and put "winter" instead of reinstall
UGB Rep 1 - Cover Middle depth sensor not operating correctly. replace
i sent a replacement to charles, he has replaced it now, aslo asked him to download data again.
shepherds: make sure change of node is reflected in dataset.
sensor install form details the node changes. nothing more to do
Two of the nodes at this farm got water inside of them and will need to get replaced. i will ship replacements for them by the end of the week. 18000430 cover rep 2 18000451 cover rep 1
Additionally, Charles visited this farm and downloaded all the data from the gateway and all the data seems to be present. will send the files to me and i will check again for anything i might have missed.