Closed Eremius closed 5 months ago
...and the log seems to show it's a casting error
Config error
Traceback (most recent call last):
File "/home/pi/klipper/klippy/configfile.py", line 35, in _get_wrapper
v = parser(self.section, option)
File "/usr/lib/python3.7/configparser.py", line 823, in getfloat
fallback=fallback, **kwargs)
File "/usr/lib/python3.7/configparser.py", line 808, in _get_conv
**kwargs)
File "/usr/lib/python3.7/configparser.py", line 802, in _get
return conv(self.get(section, option, **kwargs))
ValueError: could not convert string to float: '2 * z_offset from the "probe:z_offset" section'
During handling of the above exception, another exception occurred:
Traceback (most recent call last):
File "/home/pi/klipper/klippy/klippy.py", line 175, in _connect
self._read_config()
File "/home/pi/klipper/klippy/klippy.py", line 141, in _read_config
self.load_object(config, section_config.get_name(), None)
File "/home/pi/klipper/klippy/klippy.py", line 130, in load_object
self.objects[section] = init_func(config.getsection(section))
File "/home/pi/klipper/klippy/extras/z_calibration.py", line 469, in load_config
return ZCalibrationHelper(config)
File "/home/pi/klipper/klippy/extras/z_calibration.py", line 27, in __init__
self.clearance = config.getfloat('clearance', None, above=0.)
File "/home/pi/klipper/klippy/configfile.py", line 67, in getfloat
note_valid=note_valid)
File "/home/pi/klipper/klippy/configfile.py", line 40, in _get_wrapper
% (option, self.section))
configparser.Error: Unable to parse option 'clearance' in section 'z_calibration'
webhooks client 4134713488: New connection
webhooks client 4134713488: Client info {'program': 'Moonraker', 'version': 'v0.8.0-209-g4235789'}
Hi, this is the default from the documentation. You need to define a (float) number if you want a different value. And please use the safe_z_height property since clearance is already deprecated.
Should this value be picked up automatically by default or do you need to explicitly set it?
If you do not include this property in your config file, the default will be used (in this case two times the z_offset of your probe ...or 3mm if your probe does not have a z_offset). Or it is the value that you use with this property.
I am receiving an issue from Klipper
Unable to parse option 'clearance' in section 'z_calibration'
In the autoz.cfg file the line isclearance: 2 * z_offset from the "probe:z_offset" section
I am using a euclid probe. I am not sure if this matters but he euclid probe include (which contains the z_offset value) precedes the autoz.cfg include.
I did just notice that all the text after clearance is lt blue instead of the orange
I suspect this is a python spacing issue but I am not sure what it should be.