Hi, I don't understand what I'm supposed to be doing here Should I replace BASE_CALIBRATE_Z with BED_MESH_CALIBRATE? My code looks like this so far:


[gcode_macro CALIBRATE_Z]
rename_existing: BED_MESH_CALIBRATE
gcode:
    G28
    M117 Z-Calibration..
   # _SET_LOWER_STEPPER_CURRENT  # I lower the stepper current for homing and probing 
    Attach_Probe                # a macro for fetching the probe first
    BED_MESH_CALIBRATE
    Dock_Probe                # and parking it afterwards
    #_RESET_STEPPER_CURRENT      # resetting the stepper current
    M117
Ramalama2 commented 2 years ago

Hi, I don't understand what I'm supposed to be doing here Should I replace BASE_CALIBRATE_Z with BED_MESH_CALIBRATE? My code looks like this so far:


[gcode_macro CALIBRATE_Z]
rename_existing: BED_MESH_CALIBRATE
gcode:
    G28
    M117 Z-Calibration..
   # _SET_LOWER_STEPPER_CURRENT  # I lower the stepper current for homing and probing 
    Attach_Probe                # a macro for fetching the probe first
    BED_MESH_CALIBRATE
    Dock_Probe                # and parking it afterwards
    #_RESET_STEPPER_CURRENT      # resetting the stepper current
    M117

You don't need to do anything there.

Hi, I don't understand what I'm supposed to be doing here Should I replace BASE_CALIBRATE_Z with BED_MESH_CALIBRATE? My code looks like this so far:


[gcode_macro CALIBRATE_Z]
rename_existing: BED_MESH_CALIBRATE
gcode:
    G28
    M117 Z-Calibration..
   # _SET_LOWER_STEPPER_CURRENT  # I lower the stepper current for homing and probing 
    Attach_Probe                # a macro for fetching the probe first
    BED_MESH_CALIBRATE
    Dock_Probe                # and parking it afterwards
    #_RESET_STEPPER_CURRENT      # resetting the stepper current
    M117

You don't need anything there.

Citus made an example, for configurations where the magprobe doesn't attaches automatically. So that section you link for is exactly for that, just an example how to manually modify the calibrate_z "macro". Or to be more explicite, what to do before and after if you execute calibrate_z.

For your bed_mesh macro example, you may have or may not, attach the magprobe either. But this doesn't has anything todo with calibrate_z.

Calibrate_z and bed_mesh are separate things. Cheers

laserbeak commented 2 years ago

is there a walkthrough that teaches you how to use it? I'm pretty confused :)

Ramalama2 commented 2 years ago

What happens if you simply execute calibrate_z?

We simply include it usually at the end of print_start...

laserbeak commented 2 years ago

What happens if you simply execute calibrate_z?

running calibrate_z will home x y and z, attach the probe then immediately dock it.

We simply include it usually at the end of print_start...

What do you mean by this?

Ramalama2 commented 2 years ago

What happens if you simply execute calibrate_z?

running calibrate_z will home x y and z, attach the probe then immediately dock it.

We simply include it usually at the end of print_start...

What do you mean by this?

Omg... Yes because you use the macro above.... Comment out the macro or delete it then check what calibrate_z does 🤦

laserbeak commented 2 years ago

...sorry but the english during this whole conversation hasn't been very clear....(but I'm not judging you because of that, so what's with the attitude problem? 🤦 )

Not surprisingly, commenting out the macro does exactly what I thought it would...

 16:28:20  $ calibrate_z
16:28:20  // Unknown command:"CALIBRATE_Z"
Ramalama2 commented 2 years ago

...sorry but the english during this whole conversation hasn't been very clear....(but I'm not judging you because of that, so what's with the attitude problem? 🤦 )

Not surprisingly, commenting out the macro does exactly what I thought it would...

 16:28:20  $ calibrate_z
16:28:20  // Unknown command:"CALIBRATE_Z"

Yes, because you didn't installed the plugin correctly 🤦

laserbeak commented 2 years ago

OK, well shame on me then? :man_shrugging:

I didn't exactly find documentation to do this. it seems to be fine from fluidd... is there any documentation to properly install a plugin? or is asking setting myself up for more shame?

Ramalama2 commented 2 years ago

Ssh into your pi with putty... But with the "pi" user. If you ssh with root user, you need to enter: su - pi

Then:

cd /home/pi
git clone https://github.com/protoloft/klipper_z_calibration.git
cd klipper_z_calibration
chmod +x install.sh
./install.sh

Then you edit your moonraker.conf located in:

cd /home/pi/klipper_config/
nano moonraker.conf

And you add this to it:

[update_manager client z_calibration]
type: git_repo
path: /home/pi/klipper_z_calibration
origin: https://github.com/protoloft/klipper_z_calibration.git
install_script: install.sh

Then you restart klipper, and you will get some errors. Those means, that you have to add this to your config: https://github.com/protoloft/klipper_z_calibration/blob/master/configuration/z_calibration.cfg

You can simply download it and include it with: [include z_calibration.cfg] In your printer.cfg.

Read what those Options means and set them correctly.

Cheers

laserbeak commented 2 years ago

That's what I didn't do!! 🤦 I never included z_calibration.cfg in my printer.cfg 🤦🤦🤦 Thanks so much!! I ran calibrate_z and it doesn't attach my probe though...

 03:02:23  $ CALIBRATE_Z
03:02:23  // Probe already docked!
03:02:23  // probe: TRIGGERED
03:02:28  !! No trigger on probe after full movement
03:02:28  !! No trigger on probe after full movement

I've manually attached the probe and ran calibrate_z again

03:07:11  $ CALIBRATE_Z
03:07:11  // Docking Probe
03:07:13  // probe: TRIGGERED
03:07:18  !! No trigger on probe after full movement
03:07:18  !! No trigger on probe after full movement

​ This isn't what's supposed to happen, right? :headstone: :sweat_smile: ​As you've suggested earlier, I put it at the end of my print_start? I was hoping i could test it before printing something.

Ramalama2 commented 2 years ago

This is the minimal config, you basically need only to define this:

[z_calibration]
probe_nozzle_x: 271.5 #your endstop x pos
probe_nozzle_y: 353 #your endstop y pos
probe_switch_x: 265.7 #see the picture attached below
probe_switch_y: 331.9 #see the picture attached below
switch_offset: 0.50 #d2f, read the docs
max_deviation: 1.0 #1.0 is a good default value
speed: 50
probing_first_fast: true
start_gcode: ATTACH_PROBE #this is what you miss
end_gcode: DOCK_PROBE #this you miss surely too

1634920072243 probe_switch_x and y, are the coordinates of that point. Z-endstop needs to hit the "body" of the microswitch, not the button of the microswitch.

You can replace basically your config with my above, change the coordinates and your should be good 😘

laserbeak commented 2 years ago

Oh.... my code was backwards.... 😅

start_gcode: Dock_Probe_Unlock
before_switch_gcode: Attach_Probe
end_gcode: Dock_Probe

everything else looks about right compared to yours. I've changed mine to this:

start_gcode: Attach_Probe
#before_switch_gcode: Attach_Probe
end_gcode: Dock_Probe

Trying now.

13:54:30  $ CALIBRATE_Z
13:54:31  // Attaching Probe
13:54:34  // probe: open
13:54:38  !! No trigger on probe after full movement
13:54:39  !! No trigger on probe after full movement

I have tuning to do :) When this happens, my nozzle is at: x: 225 y:350 z: 0

I feel like I'm doing something wrong here:

probe_nozzle_x: 225    #x position of the hotend nozzle?
probe_nozzle_y: 350    #y position of the hotend nozzle?
probe_switch_x: 221    #x position of the probe switch body?
probe_switch_y: 330    #y position of the probe switch body?

IMG_20211202_142432656

probe_switch_x and y, are the coordinates of that point. Z-endstop needs to hit the "body" of the microswitch, not the button of the microswitch.

Does this mean that the body has to trigger z or just touch it?

Thanks for your patience!! :smiling_face_with_three_hearts::smiling_face_with_three_hearts::smiling_face_with_three_hearts::smiling_face_with_three_hearts:

Ramalama2 commented 2 years ago

No trigger on probe after full movement

This means simply that your klicky isn't working 😂

No contact or whatever. And according to your good picture from the side, there is Filament sticking out. You need to calibrate-z with turned on hotend and with a small retraction before, else it won't be accurate if the filament sticks out.

laserbeak commented 2 years ago

No trigger on probe after full movement

This means simply that your klicky isn't working 😂

Yes, it doesn't work when trying the calibrate_z macro. But I use it all of the time. This is what leads me to believe that my z_calibration.cfg isn't configured correctly. :thinking:

No contact or whatever. And according to your good picture from the side, there is Filament sticking out. You need to calibrate-z with turned on hotend and with a small retraction before, else it won't be accurate if the filament sticks out.

Damn it, I knew I should've removed that filament from my "awesome" ( you made a typo there ) picture. That's from changing filaments. I don't normally have that oozing from my nozzle. In this particular case, does it really make a difference, since it's not even touching the endstop?

AndrewTheWookiee commented 2 years ago

I was getting the exact same error as you, with the exact same behavior with the nozzle stopping just above the z endstop. I figured out it's because my position_endstop is -0.73, so the position_min in the z_calibration.cfg (I started with the z_calibration.cfg from the klicky probe repo) which had a default value of 0 was causing the issue. Just make sure it's commented out or set it to the same as in your main config.cfg and you should be good to go.

laserbeak commented 2 years ago

Hi! Mine was 0 also! I've set it to my position_endstop value (-0.74) and it actually starts to do its thing, but I get an error when sampling from the z endstop with the probe body:

13:42:07  $ CALIBRATE_Z
13:42:07  // Attaching Probe
13:42:10  // probe: open
13:42:15  // probe at 225.000,350.000 is z=-0.730000
13:42:16  // probe at 225.000,350.000 is z=-0.727500
13:42:18  // probe at 225.000,350.000 is z=-0.725000
13:42:20  // probe at 225.000,350.000 is z=-0.725000
13:42:22  // probe at 221.000,330.000 is z=6.347500
13:42:24  // probe at 221.000,330.000 is z=6.355000
13:42:26  // probe at 221.000,330.000 is z=6.357500
13:42:27  // probe at 221.000,330.000 is z=6.360000
13:42:27  !! Move out of range: 12.000 -7.750 22.200 [0.000]
13:42:27  !! Move out of range: 12.000 -7.750 22.200 [0.000]
AndrewTheWookiee commented 2 years ago

That looks like it successfully probed the nozzle (225,350), then probed the switch body (221,330), then it looks like it's trying to move to (12,-7.75) to probe the switch on the bed.

What are your probe_bed_x and probe_bed_y values? They should be in the middle of your bed.

For reference, here's my console from a successful calibration. First is the nozzle homing

13:08:26   $ calibrate_z
13:08:26   // Attaching Probe
13:08:28   // probe: open
13:08:33   // probe at 266.000,390.000 is z=-0.767438
13:08:35   // probe at 266.000,390.000 is z=-0.759950
13:08:37   // probe at 266.000,390.000 is z=-0.757455
13:08:39   // probe at 266.000,390.000 is z=-0.757455

Here's the switch body homing

13:08:44   // probe at 261.002,370.000 is z=0.999641
13:08:46   // probe at 261.002,370.000 is z=0.999641
13:08:48   // probe at 261.002,370.000 is z=1.002136
13:08:50   // probe at 261.002,370.000 is z=1.002136

Here's the toolhead moving the switch to the center of the bed and finishing. Note that the console shows the nozzle position, so you'll see it offset because the switch is in the actual middle.

13:08:57   // probe at 188.001,164.003 is z=1.873196
13:08:58   // probe at 188.001,164.003 is z=1.885676
13:08:59   // probe at 188.001,164.003 is z=1.885676
13:09:00   // probe at 188.001,164.003 is z=1.885676
13:09:00   // Z-CALIBRATION: ENDSTOP=-0.730 NOZZLE=-0.757 SWITCH=1.002 PROBE=1.886 --> OFFSET=-0.423915
13:09:00   // Docking Probe
13:09:05   // probe: TRIGGERED
laserbeak commented 2 years ago

Ah..that's what it was. I misread the comments in the config file. my x and y were 12 when they should've been 175. (390...wow, that's a big print bed). Thanks!!!

laserbeak commented 2 years ago

Closing now. Benchy looks great ❤️‍🔥 . Thanks again for the help!!

AndrewTheWookiee commented 2 years ago

Awesome :)

Glad everything worked out.