C5 and C2 are not connected on the positive side on the board layout #1

Closed bwattendorf closed 6 years ago

bwattendorf commented 6 years ago

When I run the DRC and show unconnected I get an error that C5 and C2 are not connected. I also get an error that pad 3 on P9 and pad 1 on P8 are not connected but it looks like they are connected when I manually trace the connection.

ok1hra commented 6 years ago

Yes you're right, C5 are connected versus the original scheme to the output. It is does not change detector function. Thanks for feedback.

bwattendorf commented 6 years ago

Thanks Dan

Bruce W1BAW

On Wed, Dec 6, 2017 at 3:08 PM, Dan OK1HRA notifications@github.com wrote:

Yes you're right, C5 are connected versus the original scheme to the output. It is does not change detector function. Thanks for feedback.

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/prusa3d/MK3_Power_Panic/issues/1#issuecomment-349759383, or mute the thread https://github.com/notifications/unsubscribe-auth/ABGFab5mOv1puB9W-gra8MHpH9LkPo7Yks5s9vRBgaJpZM4Q4fcR .

ok1hra commented 6 years ago

I see happy ham radio operator also in comerce contact. CUL on bands Bruce 73, Dan OK1HRA

2017-12-06 21:09 GMT+01:00 bwattendorf notifications@github.com:

Thanks Dan

Bruce W1BAW

On Wed, Dec 6, 2017 at 3:08 PM, Dan OK1HRA notifications@github.com wrote:

Yes you're right, C5 are connected versus the original scheme to the output. It is does not change detector function. Thanks for feedback.

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/prusa3d/MK3_Power_Panic/issues/1# issuecomment-349759383, or mute the thread https://github.com/notifications/unsubscribe-auth/ABGFab5mOv1puB9W- gra8MHpH9LkPo7Yks5s9vRBgaJpZM4Q4fcR .

— You are receiving this because you commented. Reply to this email directly, view it on GitHub https://github.com/prusa3d/MK3_Power_Panic/issues/1#issuecomment-349759736, or mute the thread https://github.com/notifications/unsubscribe-auth/ALeRx0ooyUGU5nBJq7NIS2mn4A1zRYCtks5s9vSTgaJpZM4Q4fcR .

bwattendorf commented 6 years ago

same here 73

On Wed, Dec 6, 2017 at 3:15 PM, Dan OK1HRA notifications@github.com wrote:

I see happy ham radio operator also in comerce contact. CUL on bands Bruce 73, Dan OK1HRA

Zdraví Dan Pech

Prusa Research s.r.o. Partyzánská 188/7a 170 00, Praha 7

2017-12-06 21:09 GMT+01:00 bwattendorf notifications@github.com:

Thanks Dan

Bruce W1BAW

On Wed, Dec 6, 2017 at 3:08 PM, Dan OK1HRA notifications@github.com wrote:

Yes you're right, C5 are connected versus the original scheme to the output. It is does not change detector function. Thanks for feedback.

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/prusa3d/MK3_Power_Panic/issues/1# issuecomment-349759383, or mute the thread https://github.com/notifications/unsubscribe-auth/ABGFab5mOv1puB9W- gra8MHpH9LkPo7Yks5s9vRBgaJpZM4Q4fcR .

— You are receiving this because you commented. Reply to this email directly, view it on GitHub https://github.com/prusa3d/MK3_Power_Panic/issues/1# issuecomment-349759736, or mute the thread https://github.com/notifications/unsubscribe-auth/ ALeRx0ooyUGU5nBJq7NIS2mn4A1zRYCtks5s9vSTgaJpZM4Q4fcR

.

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/prusa3d/MK3_Power_Panic/issues/1#issuecomment-349761028, or mute the thread https://github.com/notifications/unsubscribe-auth/ABGFaYcuZtbeb8I0_3LWY2MqGc_Mt45Xks5s9vXJgaJpZM4Q4fcR .

bwattendorf commented 6 years ago

Closing the issue since it is not a problem

make-ing commented 6 years ago

Hello, i also came across this error (and already opened an issue #5) and it seems very unlikely that this will work the same as described in the schematic. A capacitor (C5) of this size (10µF) will definitely delay the AC_FAULT signal. I hope you will fix either the error in the schematic or in the PCB since i think this will otherwise lead to some more questions and lot of duplicate issue when other people stumble across this inconsistency.

Thanks a lot for the great work so far!

ok1hra commented 6 years ago

yes, will be fixed in next version

bwattendorf commented 6 years ago

Dan do you guys need any Beta testers for the new Multi material upgrade?

ok1hra commented 6 years ago

probably no, sri

bwattendorf commented 6 years ago

Thanks for the Reply

On Tue, Mar 27, 2018 at 2:47 PM, Dan OK1HRA notifications@github.com wrote:

probably no, sri

— You are receiving this because you modified the open/close state. Reply to this email directly, view it on GitHub https://github.com/prusa3d/MK3_Power_Panic/issues/1#issuecomment-376633573, or mute the thread https://github.com/notifications/unsubscribe-auth/ABGFaTo7xJR45y3Xxh5Fq1Mvjy1RwolTks5tiok4gaJpZM4Q4fcR .

boelle commented 6 years ago

how can i fix this now? i mean it must sure be a simple task?