pulquero / BatteryAggregator

MIT License
32 stars 8 forks source link

Since v3.0.60 Again CCL = 0 and DCL =0 #40 #50

Closed Rubens974 closed 3 months ago

Rubens974 commented 3 months ago

Hi, Since v3.0.60 I have again the same issue like in #40 . Here are logs @40000000664641eb35bfc5f4.s.txt @400000006646423711b8f2fc.s.txt @400000006646428535aaee04.s.txt current.txt

image

New logs after reboot

@40000000664646cf11e93e44.s.txt @400000006646474b11dd0d2c.s.txt @400000006646465911d15144.s.txt current.txt

Regards

pulquero commented 3 months ago

Sorry about that. What is the value of /Info/MaxChargeCurrent and /Io/AllowToCharge for one of your batteries? I'm guessing one is 0 the other is null and I'm checking the wrong one.

Rubens974 commented 3 months ago

Hi, Bank 1: CCL 200A and CVL 54.5V Bank 2: CCL 175A and CVL 53.2V BatteryAggregator: null image image

image

Logs @400000006646ba1f00deb5ac.s.txt @400000006646ba6e24f70d04.s.txt current.txt

Thank you

pulquero commented 3 months ago

It was an entirely different issue to what I thought, should be fixed in v3.0.61.