B1.9 Advertising Problem #155

Closed xfactory9025 closed 2 years ago

xfactory9025 commented 2 years ago

My device hardware B1.9. I installed ATC_V34d. The image is as seen in the picture. Temperature and humidity information shows as no value on the phone. IMG_6616

pvvx commented 2 years ago

https://pvvx.github.io/ATC_MiThermometer/TelinkMiFlasher.html Log: Hardware Version: LYWSD03MMC B1.9, Software Version: 3.4, Sensor: SHT4x ?

xfactory9025 commented 2 years ago

https://pvvx.github.io/ATC_MiThermometer/TelinkMiFlasher.html Log: Hardware Version: LYWSD03MMC B1.9, Software Version: 3.4, Sensor: SHT4x ?

Yes

pvvx commented 2 years ago

The reasons for this behavior have not been established. More suitable option - LCD from version 1.4, LCD driver from 1.9? Could you clarify the production date on the box?

xfactory9025 commented 2 years ago

IMG_6617

Protoncek commented 2 years ago

I just received two of those (2021.08) and they have B1.9 (i checked by opening them). Flashed both of them with pvvx succesfully.

xfactory9025 commented 2 years ago

Az iki önce tane (2021.08) aldım ve B1.9'a sahipler (açarak kontrol ettim). Her ikisi de etkili bir şekilde pvx ile flashladım.

I did not understand why this happened.

pvvx commented 2 years ago

Xiaomi LYWSD03MMC Original Firmware v1.0.0_0130 working fine?

xfactory9025 commented 2 years ago

Xiaomi LYWSD03MMC Original Firmware v1.0.0_0130 working fine?

yes

pvvx commented 2 years ago

What version of HW does the original firmware show?

xfactory9025 commented 2 years ago

B1.9

xfactory9025 commented 2 years ago

I have installed atc1441 version. The values ​​do not appear in the advertisement broadcast on the phone, but when used with the esp32 code here, the values ​​appear on the serial monitor. Working with Esp32 solved my problem.