Failed to load image "Image has an invalid orientation (code IRI) " #69

Open dhinkris opened 1 year ago

dhinkris commented 1 year ago

I am trying to open a .nii.gz image. For a specific set of 'affine' matrix, ITK snap throws theImage has an invalid orientation (code IRI) error. The header seems correct (Right-to-Left, Anterior-to-Posterior, Inferior-to-Superior) in which case it is an RAI orientation but I see the error as above. It seems like ITK-Snap internally computes the orientation based on the affine matrix which seems to be causing this issue. This works fine FSLEyes/3D Slicer. Your help is much appreciated.

The error can be replicated with the below snippet.

import nibabel as nib
import numpy as np

data=np.random.random((256,256,56))
affine=[[-0.656692, -0.676962, 0.332383, -0.000000],
        [0.360389, -0.668844, -0.650205, -0.000000],
        [0.662477, -0.307197, 0.683194, 0.000000],
        [0.000000, 0.000000, 0.000000, 1.000000]
nifti_img=nib.Nifti1Image(data, affine=affine
nib.save(nifti_img, "orientation_test.nii.gz")

Below is the header information of that specific nifti file sizeof_hdr 348 data_type FLOAT64 dim0 3 dim1 256 dim2 256 dim3 56 dim4 1 dim5 1 dim6 1 dim7 1 vox_units Unknown time_units Unknown datatype 64 nbyper 8 bitpix 64 pixdim0 1.000000 pixdim1 1.000000 pixdim2 1.000000 pixdim3 1.000000 pixdim4 1.000000 pixdim5 1.000000 pixdim6 1.000000 pixdim7 1.000000 vox_offset 352 cal_max 0.000000 cal_min 0.000000 scl_slope 1.000000 scl_inter 0.000000 phase_dim 0 freq_dim 0 slice_dim 0 slice_name Unknown slice_code 0 slice_start 0 slice_end 0 slice_duration 0.000000 toffset 0.000000 intent Unknown intent_code 0 intent_name intent_p1 0.000000 intent_p2 0.000000 intent_p3 0.000000 qform_name Unknown qform_code 0 qto_xyz:1 -0.656692 -0.676962 0.332383 -0.000000 qto_xyz:2 0.360389 -0.668844 -0.650205 -0.000000 qto_xyz:3 0.662477 -0.307197 0.683194 0.000000 qto_xyz:4 0.000000 0.000000 0.000000 1.000000 qform_xorient Right-to-Left qform_yorient Anterior-to-Posterior qform_zorient Inferior-to-Superior sform_name Unknown sform_code 2 sto_xyz:1 -0.656692 -0.676962 0.332383 -0.000000 sto_xyz:2 0.360389 -0.668844 -0.650205 -0.000000 sto_xyz:3 0.662477 -0.307197 0.683194 0.000000 sto_xyz:4 0.000000 0.000000 0.000000 1.000000 sform_xorient Right-to-Left sform_yorient Anterior-to-Posterior sform_zorient Inferior-to-Superior file_type NIFTI-1+ file_code 1 descrip aux_file

Any suggestions would be really helpful.

Thank you. Regards, Dhinesh

fx-carton commented 1 year ago

You're getting this error because ITK-SNAP tries to figure out which axis maps to coronal, axial and sagital views. (Something Slicer does not, it has red/green/yellow views with no anatomical meaning in particular). To do this, ITK-SNAP assumes that the matrix is the transform to LPI and uses that to figure out the mapping. In your case, the maximum (in absolute value) of columns 1 and 3 are both in row 3, so no mapping is possible.

A workaround is to reset the transform to identity, however this means that if you open another image, the shared cursor feature won't work.

What kind of image are you trying to open? I suspect it's not MRI/scanner for which L/R, P/A, I/S makes sense. I've had the case for freehand ultrasound volumes for which the transform is arbitrary and no axis can be meaningfully labelled as L/R, P/A or I/S. It would be helpful that in case no mapping is possible, ITK-SNAP assigns an arbitrary one and still opens the image.

dhinkris commented 1 year ago

@fx-carton Thanks for clarifying this. Now I clearly understand the problem.

I am working on fetal MRI scans. The modality is T2 SSFSE and we perform three acquisitions close which closely resemble axial, sagittal, and coronal. And then perform Slice to Volume reconstruction(overlay based on registration). If I reset them to identify affine the images will open, but the shared cursor won't be in place as you mentioned which means the position of the acquisitions is far away from each other relative to the origin. This gets complicated during the reconstruction step as it is heavily based on registration. Yes, it would be helpful if ITK-SNAP assigns an arbitration orientation and opens up the images.

My requirement is to transform all three acquisitions to a valid orientation but still retain their relative positions. Let me know if you understood the problem and have any workaround for this.

Thanks again for taking the time to explain this. Very helpful.

Regards, Dhinesh

cbhushan commented 1 year ago

I am also facing the same issue. The data is from real clinical shoulder MRI case. Any ideas?

Here is the direction cosine matrix:

[[-0.71844119  0.06575722 -0.69247257]
 [ 0.67544218  0.30380508 -0.67192283]
 [ 0.16619304 -0.95046224 -0.26268128]]

Image Orientation (Patient) [dicom tag (0020,0037)] in the original dicom is -0.718441\0.675442\0.166193\0.0657572\0.303805\-0.950462

It loads fine in slicer3D and dicom viewers.