Transformation of the district heating network to include three temperature:
Low temperature (LT)
Medium temperature (MT)
High temperature (HT)
The transformation includes:
Added detail for producers that specifies which temperature level heat they can supply
Added detail for consumers that specifies which temperature level heat they can consume
Updated calculation for heat_network that allows multiple temperature levels
Updated costs attributes for district heating
Updates to slides, inputs and charts
All initial data is set to HT, meaning that all existing scenarios are migrated to fully take place on the HT district heating network, impact on scenarios is therefore minimal
Transformation of the district heating network to include three temperature:
The transformation includes:
Linked PR's: