Call floating wires "z" instead of "x" #94

Open ausbin opened 1 year ago

ausbin commented 1 year ago

Blue wires are high impedance, and the standard name for that state is z, not x (e.g., in Verilog), so make CircuitSim display "z" instead of "x". Also remove the spots in the documentation where floating is called "uninitialized."

To me at least, this screenshot justifies this change:

image