railcraft-reborn / railcraft

Redefine your rails
Other
94 stars 24 forks source link

Steam Boiler generating wrong amount of mB/t #147

Open Susjin opened 11 months ago

Susjin commented 11 months ago

Is there an existing issue for this?

Description of the Bug

From testing with the Advanced Generators mod, I can mostly say for sure that the boiler using High Pressure Steam Boiler Tank is generating less mB/t of Steam.

It's supossed to generate 20mB/t for each block. I have 36, so it should be 720mB/t, but, according to the AdvGenerators turbine consumption, it's generating around 361 mB/t

I can't say for sure that it's a Railcraft issue, but it's a weird bug.

Railcraft Reborn version

1.0.9

NeoForge/Forge version

47.1.76

Minecraft version

1.20.1

Minecraft server

Yes

To Reproduce

  1. Build a 3x4x3 Steam Boiler using High Pressure Steam Boiler Tank
  2. Build a Advanced Generators turbine using one Composite Turbine (1,000 RF/t)
  3. Check the Steam consumption when the backlog goes out.

Expected behavior

That the Boiler would generate 720mB/t of Steam.

Logs & Environment

No response

Screenshots & Video

Advanced Generators turbine controller interface: image

Edivad99 commented 10 months ago

Could you also try in 1.12.2? The code has not undergone major changes and is perhaps the same in 1.12.2