Issue with latest bus master software version 1.6.7 #283

Closed rsiddula closed 12 years ago

rsiddula commented 12 years ago

Hello,

It is very nice tool and appreciated your efforts.

I have installed latest version and tried but not working so I have installed older version 1.6.4 then its working.

I am able to see message from the ECU on the version 1.6.4 but not on v1.6.7.I have folloed same procedure for both the version.

Note: 1.6.7 is working with Vector XL and not working with PEAK.

Please look into the issue and let me know.

Thanks.

etas-lorenz commented 12 years ago

We introduced a new project configuration format. Old settings may be lost. So, have you checked that the controller configuration (baudrate, sample point) is correct?

rsiddula commented 12 years ago

Yes, I hadn't used old version configuration file.

I have followed below steps after installation: Step 1: Configue->Hardware Interface and selected PEAK USB Step 2: Configue->Controller - Baud Rate to 250kbps,BTR0 to 0x43,BTR1 to 0x14, No.Of sample/Bit to 1 abd Warning Limit to 96. Step 3: Functions->Connect

Please let me know if the above settings are wrong.

Thanks in advance.

rsiddula commented 12 years ago

Hello,

I got another issue with Database file.

Got error log while converting DBC to DBF using utilities option and its working data base file as I am using for CANalyzer.

I have tried to resolve those errors but most of the errros are related to signals.

Please look into the below errors:

Conversion Error Log

MSG_ID: 419236350 MSG_TYPE: X MSG_NAME: HRLFC SIG_NAME: HighResolutionEngTotalFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HighResolutionEngTripFuel, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 413335294 MSG_TYPE: X MSG_NAME: DM32 SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486455294 MSG_TYPE: X MSG_NAME: LF SIG_NAME: TotalEngCruiseTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419355902 MSG_TYPE: X MSG_NAME: IO SIG_NAME: EngTotalIdleHours, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: EngTotalIdleFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419358206 MSG_TYPE: X MSG_NAME: HOURS SIG_NAME: EngTotalRevolutions, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: EngTotalHoursOfOperation, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 217966334 MSG_TYPE: X MSG_NAME: HBS SIG_NAME: HydBrakePressCircuit2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HydBrakePressCircuit1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486455550 MSG_TYPE: X MSG_NAME: GTFI SIG_NAME: TripDriveFuelEconomy, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripCruiseFuelUsed, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripVehicleIdleFuelUsed, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TrpPTOGovernorNonmovingFuelUsed, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripPTOGovernorMovingFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TripDriveFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486454014 MSG_TYPE: X MSG_NAME: GFI1 SIG_NAME: TotalEngPTOGovernorFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486453246 MSG_TYPE: X MSG_NAME: GFC SIG_NAME: TotalFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TripFuel, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 217062654 MSG_TYPE: X MSG_NAME: RGAAQ SIG_NAME: RqdGnrtrAvrgLneLineACRMSVoltage, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 217060862 MSG_TYPE: X MSG_NAME: RGTARP SIG_NAME: RqGenOverallPowerFactorLagging, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: RqGeneratorTotalACReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419281150 MSG_TYPE: X MSG_NAME: DM26 SIG_NAME: NMHCConvertingCatalystCompleted, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NOxConvertingCatalystAdsorberCom, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DieselParticulateFilterCompleted, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: BoostPressureControlSystemComple, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NMHCConvertingCatalystEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NOxConvertingCatalystAdsorberEna, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DieselParticulateFilterEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: BoostPressureControlSystemEnable, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ComprehensiveComptMonComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416612094 MSG_TYPE: X MSG_NAME: DM18 SIG_NAME: SecurityEntityLengthHigh, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SecurityEntityLength, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419361790 MSG_TYPE: X MSG_NAME: VP SIG_NAME: Longitude, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Latitude, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419358718 MSG_TYPE: X MSG_NAME: VH SIG_NAME: TotalPowerTakeoffHours, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TotalVehicleHours, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419348990 MSG_TYPE: X MSG_NAME: VDHR SIG_NAME: HighResolutionTripDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HghRslutionTotalVehicleDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419356926 MSG_TYPE: X MSG_NAME: VD SIG_NAME: TotalVehicleDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TripDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486455038 MSG_TYPE: X MSG_NAME: TVI SIG_NAME: TripCruiseDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486453502 MSG_TYPE: X MSG_NAME: TTI2 SIG_NAME: TripAirCompressorOnTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripIdleTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripEngRunningTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripPTOGovernorTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TripCruiseTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486454526 MSG_TYPE: X MSG_NAME: TTI1 SIG_NAME: TripTimeInDerateByEng, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripTimeInGearDown, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripTimeInTopGear, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TripTimeInVSL, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419282174 MSG_TYPE: X MSG_NAME: TR4 SIG_NAME: DriversFareboxSecurityCode, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: AssignedBlock, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: AssignedRun, STATUS: Invalid start bit, ACTION: Signal Discarded

MSG_ID: 486456318 MSG_TYPE: X MSG_NAME: TFI SIG_NAME: TripFanOnTimeDueToA_CSystem, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripFanOnTimeDueToAManualSwitch, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripFanOnTimeDueToEngSystem, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TripFanOnTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486456062 MSG_TYPE: X MSG_NAME: TDI SIG_NAME: TripDistanceInTopGear, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripGearDownDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TripDistanceOnVSL, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419357182 MSG_TYPE: X MSG_NAME: RC SIG_NAME: PercentTorqueAtPeakTorquePoint5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: ReferenceRetarderTorque, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: RetarderSpeedAtPeakTorquePoint5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: PercentTorqueAtPoint4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: RetarderSpeedAtPoint4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: PercentTorqueAtPoint3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: RetarderSpeedAtPoint3, STATUS: Invalid start bit, ACTION: Signal Discarded

MSG_ID: 486446590 MSG_TYPE: X MSG_NAME: RBI SIG_NAME: EngOperationTimeSinceRebuild, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 218002942 MSG_TYPE: X MSG_NAME: LVD SIG_NAME: LaserStrikeDataLatency, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486455806 MSG_TYPE: X MSG_NAME: LTFI SIG_NAME: TripDriveFuelEconomy, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripCruiseFuelUsed, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripVehicleIdleFuelUsed, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TrpPTOGovernorNonmovingFuelUsed, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripPTOGovernorMovingFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TripDriveFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 218002686 MSG_TYPE: X MSG_NAME: LSP SIG_NAME: BldHeightSetPointHighResolution, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486454270 MSG_TYPE: X MSG_NAME: LFI SIG_NAME: TotalEngPTOGovernorFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419359230 MSG_TYPE: X MSG_NAME: LFC SIG_NAME: EngTotalFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: EngTripFuel, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486396414 MSG_TYPE: X MSG_NAME: FMS SIG_NAME: FMSstandardSWversionSupported, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419336446 MSG_TYPE: X MSG_NAME: ETH SIG_NAME: EngTorqueLimit6AxleInput, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngTorqueLimit5Switch, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngTorqueLimit4Trans, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngTorqueLimit3Trans, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TransGearRatio3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngTorqueLimit2Trans, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TransGearRatio2, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngTorqueLimit1Trans, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TransGearRatio1, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngTorqueLimitFeature, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TorqueLimitingFeatureStatus, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: CalibRecordDurationTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: CalibRecordStartYear, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: CalibRecordStartDay, STATUS: Invalid start bit, ACTION: Signal Discarded

MSG_ID: 486453758 MSG_TYPE: X MSG_NAME: EH SIG_NAME: TotalECURunTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TotalECUDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419357694 MSG_TYPE: X MSG_NAME: EC1 SIG_NAME: SupportTSC1CtrlPurposeGroup4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SupportTSC1CtrlPurposeGroup3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SupportTSC1CtrlPurposeGroup2, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SupportTSC1CtrlPurposeGroup1, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SupportVariableRateTSC1Message, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngDefaultTorqueLimit, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngMomentOfInertia, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngExRngRqdSpdCtrlRngUpperLimit, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngRqdTorqueCtrlRangeUpperLimit, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngRqdTorqueCtrlRangeLowerLimit, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngRqedSpeedCtrlRangeUpperLimit, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngRqedSpeedCtrlRangeLowerLimit, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngMxMomentaryOverrideTimeLimit, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngMxMmntaryOverrideSpeedPoint7, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngReferenceTorque, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngGainOfEndspeedGovernor, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngSpeedAtHighIdlePoint6, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngPercentTorqueAtPoint5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngSpeedAtPoint5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngPercentTorqueAtPoint4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngSpeedAtPoint4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngPercentTorqueAtPoint3, STATUS: Invalid start bit, ACTION: Signal Discarded

MSG_ID: 486456574 MSG_TYPE: X MSG_NAME: CBI SIG_NAME: TripServiceBrakeApps, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripServiceBrakeDistance, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TripCompressionBrakeDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: TotalCompressionBrakeDistance, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 15739902 MSG_TYPE: X MSG_NAME: CN SIG_NAME: CrashType, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419258622 MSG_TYPE: X MSG_NAME: DM40 SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419258878 MSG_TYPE: X MSG_NAME: DM39 SIG_NAME: SysCumulativeContinuousMITime, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 144834302 MSG_TYPE: X MSG_NAME: DM33 SIG_NAME: AECDEngineHours1Timer2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: AECDEngineHours1Timer1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 413400830 MSG_TYPE: X MSG_NAME: DM31 SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419272958 MSG_TYPE: X MSG_NAME: AT1HI SIG_NAME: Aftrtrtmnt1AvrgTmBtwnActvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TtlNmbrOfActvRgnrtnMn, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TtlNmbrOfActvRgnrtnIn, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TtlNmbrOfPssvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TtlPssvRgnrationTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TtlNmbrOfActvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtreatment1TotalDisabledTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TtalRegenerationTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Aftertreatment1TotalFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 413466366 MSG_TYPE: X MSG_NAME: DM30 SIG_NAME: TestLimitMinimum, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: TestLimitMaximum, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419265534 MSG_TYPE: X MSG_NAME: AT1S SIG_NAME: DslPrtcltFltr1TmSncLstActvRgnrtn, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419265022 MSG_TYPE: X MSG_NAME: AT1TI SIG_NAME: Aftrtrtmnt1TrpNmbrOfActvRgnrtnMn, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TrpNmbrOfActvRgnrtnIn, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TrpNmbrOfPssvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TrpPssvRgnrationTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TrpNmbrOfActvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftertreatment1TripDisabledTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt1TrpActvRgnrationTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Aftertreatment1TripFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419273214 MSG_TYPE: X MSG_NAME: AT2HI SIG_NAME: Aftrtrtmnt2AvrgTmBtwnActvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TtlNmbrOfActvRgnrtnMn, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TtlNmbrOfActvRgnrtnIn, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TtlNmbrOfPssvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TtlPssvRgnrationTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TtlNmbrOfActvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtreatment2TotalDisabledTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TtalRegenerationTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Aftertreatment2TotalFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419265278 MSG_TYPE: X MSG_NAME: AT2S SIG_NAME: DslPrtcltFltr2TmSncLstActvRgnrtn, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419264766 MSG_TYPE: X MSG_NAME: AT2TI SIG_NAME: Aftrtrtmnt2TrpNmbrOfActvRgnrtnMn, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TrpNmbrOfActvRgnrtnIn, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TrpNmbrOfPssvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TrpPssvRgnrationTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TrpNmbrOfActvRgnrtns, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftertreatment2TripDisabledTime, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: Aftrtrtmnt2TrpActvRgnrationTime, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Aftertreatment2TripFuelUsed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 417595134 MSG_TYPE: X MSG_NAME: DM7 SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419352574 MSG_TYPE: X MSG_NAME: DM6 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419352318 MSG_TYPE: X MSG_NAME: DM5 SIG_NAME: NMHCConvertingCatalystStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NOxConvertingCatalystAdsorberSta, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DieselParticulateFilterStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: BoostPressureControlSystemStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NMHCConvertingCatalystSupport, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NOxConvertingCatalystAdsorberSup, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DieselParticulateFilterSupport, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: BoostPressureControlSystemSuppor, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonSupp, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ComprehensiveComponentMonSupp, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringSupport, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419352062 MSG_TYPE: X MSG_NAME: DM4 SIG_NAME: WheelBasedVehicleSpeed, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngineCoolantTemperature, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: EngPercentLoadAtCurrentSpeed, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419280894 MSG_TYPE: X MSG_NAME: DM25 SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419280638 MSG_TYPE: X MSG_NAME: DM24 SIG_NAME: SPNDataLength3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SPNSupported3High, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SPNSupportTypeSTR3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SPNSupportTypeSTR2, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SPNSupportTypeEFF3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: SPNSupported3, STATUS: Invalid start bit, ACTION: Signal Discarded

MSG_ID: 419280382 MSG_TYPE: X MSG_NAME: DM23 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 415497982 MSG_TYPE: X MSG_NAME: DM22 SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 415432446 MSG_TYPE: X MSG_NAME: DM20 SIG_NAME: ApplSysMonitorDenominator, STATUS: Invalid start bit, ACTION: Signal Discarded

MSG_ID: 419351550 MSG_TYPE: X MSG_NAME: DM2 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416546558 MSG_TYPE: X MSG_NAME: DM19 SIG_NAME: CalibrationID4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: CalibrationID3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: CalibrationID2, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: CalibrationID1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: CalibrationVerificationNumber, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416743166 MSG_TYPE: X MSG_NAME: DM17 SIG_NAME: BootLoadData, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416808702 MSG_TYPE: X MSG_NAME: DM16 SIG_NAME: RawBinaryData, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NumberOfOccurance, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416874238 MSG_TYPE: X MSG_NAME: DM15 SIG_NAME: NumberAllowed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416939774 MSG_TYPE: X MSG_NAME: DM14 SIG_NAME: NumberRequested, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419353854 MSG_TYPE: X MSG_NAME: DM12 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419353342 MSG_TYPE: X MSG_NAME: DM10 SIG_NAME: TestIdentifierSupported, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351294 MSG_TYPE: X MSG_NAME: DM1 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419297278 MSG_TYPE: X MSG_NAME: UTACR SIG_NAME: UtilityTotalReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419297534 MSG_TYPE: X MSG_NAME: UTACP SIG_NAME: UtilityTotalApparentPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: UtilityTotalRealPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419294718 MSG_TYPE: X MSG_NAME: UTACE SIG_NAME: UtilityTotalKWHoursImport, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: UtilityTotalKWHoursExport, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419294974 MSG_TYPE: X MSG_NAME: UPCACR SIG_NAME: UtilityPhaseCReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419295230 MSG_TYPE: X MSG_NAME: UPCACP SIG_NAME: UtilityPhaseCApparentPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: UtilityPhaseCRealPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419295742 MSG_TYPE: X MSG_NAME: UPBACR SIG_NAME: UtilityPhaseBReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419295998 MSG_TYPE: X MSG_NAME: UPBACP SIG_NAME: UtilityPhaseBApparentPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: UtilityPhaseBRealPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419296510 MSG_TYPE: X MSG_NAME: UPACCR SIG_NAME: UtilityPhaseAReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419296766 MSG_TYPE: X MSG_NAME: UPAACP SIG_NAME: UtilityPhaseAApparentPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: UtilityPhaseARealPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419300606 MSG_TYPE: X MSG_NAME: GTACR SIG_NAME: GeneratorTotalReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419300862 MSG_TYPE: X MSG_NAME: GTACP SIG_NAME: GeneratorTotalApparentPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: GeneratorTotalRealPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419298046 MSG_TYPE: X MSG_NAME: GTACE SIG_NAME: GeneratorTotalKWHoursImport, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: GeneratorTotalKWHoursExport, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419298302 MSG_TYPE: X MSG_NAME: GPCACR SIG_NAME: GeneratorPhaseCReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419298558 MSG_TYPE: X MSG_NAME: GPCACP SIG_NAME: GeneratorPhaseCApparentPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: GeneratorPhaseCRealPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419299070 MSG_TYPE: X MSG_NAME: GPBACRP SIG_NAME: GeneratorPhaseBReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419299326 MSG_TYPE: X MSG_NAME: GPBACP SIG_NAME: GeneratorPhaseBApparentPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: GeneratorPhaseBRealPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419299838 MSG_TYPE: X MSG_NAME: GPAACR SIG_NAME: GeneratorPhaseAReactivePower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419300094 MSG_TYPE: X MSG_NAME: GPAACP SIG_NAME: GeneratorPhaseAApparentPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: GeneratorPhaseARealPower, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486411774 MSG_TYPE: X MSG_NAME: WSMSTR SIG_NAME: NumberOfMembers, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419354878 MSG_TYPE: X MSG_NAME: CA SIG_NAME: AddressAssignment, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: IdentityNumber, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 418316030 MSG_TYPE: X MSG_NAME: ACL SIG_NAME: IdentityNumber, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 415956734 MSG_TYPE: X MSG_NAME: XFER SIG_NAME: ShrtNameOfActualReportingDevice, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419255550 MSG_TYPE: X MSG_NAME: DM52 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419255806 MSG_TYPE: X MSG_NAME: DM51 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419256062 MSG_TYPE: X MSG_NAME: DM50 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419256318 MSG_TYPE: X MSG_NAME: DM49 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419256574 MSG_TYPE: X MSG_NAME: DM48 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419256830 MSG_TYPE: X MSG_NAME: DM47 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419257086 MSG_TYPE: X MSG_NAME: DM46 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419257342 MSG_TYPE: X MSG_NAME: DM45 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419257598 MSG_TYPE: X MSG_NAME: DM44 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419257854 MSG_TYPE: X MSG_NAME: DM43 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419258110 MSG_TYPE: X MSG_NAME: DM42 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419258366 MSG_TYPE: X MSG_NAME: DM41 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 413138686 MSG_TYPE: X MSG_NAME: DM35 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419266814 MSG_TYPE: X MSG_NAME: DM28 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419267326 MSG_TYPE: X MSG_NAME: DM27 SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DTC1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 1073741824 MSG_TYPE: X MSG_NAME: VECTOR__INDEPENDENT_SIG_MSG SIG_NAME: TrailerWeight, STATUS: No error, ACTION: Signal Discarded SIG_NAME: ReferenceTirePressSetting, STATUS: No error, ACTION: Signal Discarded SIG_NAME: ReferenceTirePress, STATUS: No error, ACTION: Signal Discarded SIG_NAME: TirePressThresholdDetection, STATUS: No error, ACTION: Signal Discarded SIG_NAME: TireAirLeakageRate, STATUS: No error, ACTION: Signal Discarded SIG_NAME: CTIWheelEndElectricalFault, STATUS: No error, ACTION: Signal Discarded SIG_NAME: CTITireStatus, STATUS: No error, ACTION: Signal Discarded SIG_NAME: CTIWheelSensorStatus, STATUS: No error, ACTION: Signal Discarded SIG_NAME: TireTemp, STATUS: No error, ACTION: Signal Discarded SIG_NAME: TirePress, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop90Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop89Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop88Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop87Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop86Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop85Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop84Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop83Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop82Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop81Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop80Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop79Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop78Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop77Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop76Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop75Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop74Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop73Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop72Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop71Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop70Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop69Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop68Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop67Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop66Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop65Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop64Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop63Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop61Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop60Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop59Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop58Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop57Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop56Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop55Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop54Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop53Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop52Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop51Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop50Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop49Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop48Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop47Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop46Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop45Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop44Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop43Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop42Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop41Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop40Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop39Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop38Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop37Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop36Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop35Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop34Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop33Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop32Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop31Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop30Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop29Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop28Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop27Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop26Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop25Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop24Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop23Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop22Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop21Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop20Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop19Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop18Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop17Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop16Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop15Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop14Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop13Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop12Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop11Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop10Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop9Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop8Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop7Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop6Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop5Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop4Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop3Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop2Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SpecialIgnitorLoop1Resistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SdBgIgnitorLoop2RightResistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SdBgIgnitorLoop1RightResistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SdBagIgnitorLoop2LeftResistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: SdBagIgnitorLoop1LeftResistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: PssngrBltTnsnrIgntrLpResistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: DrvrBltTnsnrIgntrLoopResistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: PssngrArbgIgntrLp2ndStgRsstance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: DrvrArbgIgntrLp2ndStgResistance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: PssngrArbgIgntrLp1stStgRsstance, STATUS: No error, ACTION: Signal Discarded SIG_NAME: DrvrArbgIgntrLp1stStgResistance, STATUS: No error, ACTION: Signal Discarded

RBEI-VENKAT commented 12 years ago

The error ACTION: Value Set to default, will come when the dbc signals are defined with same Minimum and Maximum value.The converter will change these signal values to their default values.

The error ACTION: Signal Discarded will come, if dbc Signal is not associated to any dbc message.

rsiddula commented 12 years ago

Hello Venkat,

Here I got different errors like:

  1. STATUS:No error,ACTION: Signal Discarded
  2. STATUS: Invalid Max or Min value., ACTION: Value Set to default --
  3. STATUS: Invalid start bit, ACTION: Signal Discarded

Please let me know what type of errors we can ignore from the above.

RBEI-VENKAT commented 12 years ago
  1. STATUS:No error,ACTION: Signal Discarded, can be ignored since the signal is not used in any message.
  2. STATUS: Invalid Max or Min value., ACTION: Value Set to default, can be ignored since the maximum and values are set to default values
  3. Error STATUS: Invalid start bit, ACTION: Signal Discarded, is a real error.Can u check the start bit of signal in message (Ex DM43).Probably that value may be out of range compared to message length.

Also can you provide the information like the BUSMASTER version you are currently using and the Database Protocol type (CAN or J1939).

rsiddula commented 12 years ago

Hello,

I have tried to configure dbf file (with above errors in the error log) to my configuration but got “Invalid DBF File” message on the message window.

and more over its working DBC for CANcase.

Please go through it and let me know your thoughts on this.

rsiddula commented 12 years ago

Currently I am using 1.6.4 as 1.6.7 is not working with PEAK USB.

I have checked length of DM43 message and it is 22 bytes i.e 176 bits.

SIG_NAME: DTC5, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC4, STATUS: Invalid start bit, ACTION: Signal Discarded SIG_NAME: DTC3, STATUS: Invalid start bit, ACTION: Signal Discarded

DTC3: start bit is 80 and its length is 32bits DTC4: start bit is 112 and its length is 32 bits DTC5:start bit is 144 and its length is 32 bits.

I think above are within the range.

Sorry I didnt understand Database Protocol type (CAN or J1939) .Do we have seperate database file for CAN and j1939?

RBEI-VENKAT commented 12 years ago

Since some Messages are having the length more than 8bytes, I think the dbc file is having some higher level protocol(like J1939) messages. So, when you try to associate the converted file as CAN database file, BUSMASTER was failing.

rsiddula commented 12 years ago

Ok..Then how to convert J1939 DBC to DBF file using busmaster software v1.6.4. This option is available in v 1.6.7 and got same errors.

I have used two below options for conversions and got same errors in the error log. 1) J1939 DBC to DBF 2) DBC to DBF

Below are the errors. Conversion Error Log

MSG_ID: 413335294 MSG_TYPE: X MSG_NAME: DM32 SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 217966334 MSG_TYPE: X MSG_NAME: HBS SIG_NAME: HydBrakePressCircuit2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HydBrakePressCircuit1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 217060862 MSG_TYPE: X MSG_NAME: RGTARP SIG_NAME: RqGenOverallPowerFactorLagging, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419281150 MSG_TYPE: X MSG_NAME: DM26 SIG_NAME: NMHCConvertingCatalystCompleted, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NMHCConvertingCatalystEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NOxConvertingCatalystAdsorberCom, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NOxConvertingCatalystAdsorberEna, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DieselParticulateFilterCompleted, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DieselParticulateFilterEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: BoostPressureControlSystemComple, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: BoostPressureControlSystemEnable, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ComprehensiveComptMonComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416612094 MSG_TYPE: X MSG_NAME: DM18 SIG_NAME: SecurityEntityLengthHigh, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SecurityEntityLength, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 218002942 MSG_TYPE: X MSG_NAME: LVD SIG_NAME: LaserStrikeDataLatency, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 15739902 MSG_TYPE: X MSG_NAME: CN SIG_NAME: CrashType, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419258622 MSG_TYPE: X MSG_NAME: DM40 SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 413466366 MSG_TYPE: X MSG_NAME: DM30 SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 417595134 MSG_TYPE: X MSG_NAME: DM7 SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419352318 MSG_TYPE: X MSG_NAME: DM5 SIG_NAME: BoostPressureControlSystemStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DieselParticulateFilterStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NOxConvertingCatalystAdsorberSta, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NMHCConvertingCatalystStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: BoostPressureControlSystemSuppor, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: DieselParticulateFilterSupport, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NOxConvertingCatalystAdsorberSup, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NMHCConvertingCatalystSupport, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringSupport, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonSupp, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ComprehensiveComponentMonSupp, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 415497982 MSG_TYPE: X MSG_NAME: DM22 SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416743166 MSG_TYPE: X MSG_NAME: DM17 SIG_NAME: BootLoadData, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416808702 MSG_TYPE: X MSG_NAME: DM16 SIG_NAME: RawBinaryData, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: NumberOfOccurance, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416874238 MSG_TYPE: X MSG_NAME: DM15 SIG_NAME: NumberAllowed, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 416939774 MSG_TYPE: X MSG_NAME: DM14 SIG_NAME: NumberRequested, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419353342 MSG_TYPE: X MSG_NAME: DM10 SIG_NAME: TestIdentifierSupported, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486411774 MSG_TYPE: X MSG_NAME: WSMSTR SIG_NAME: NumberOfMembers, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419354878 MSG_TYPE: X MSG_NAME: CA SIG_NAME: IdentityNumber, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 418316030 MSG_TYPE: X MSG_NAME: ACL SIG_NAME: IdentityNumber, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 415956734 MSG_TYPE: X MSG_NAME: XFER SIG_NAME: ShrtNameOfActualReportingDevice, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 1073741824 MSG_TYPE: X MSG_NAME: VECTOR__INDEPENDENT_SIG_MSG SIG_NAME: TrailerWeight, STATUS: No error, ACTION: Signal Discarded SIG_NAME: ReferenceTirePressSetting, STATUS: No error, ACTION: Signal Discarded SIG_NAME: ReferenceTirePress, STATUS: No error, ACTION: Signal Discarded SIG_NAME: TirePressThresholdDetection, STATUS: No error, ACTION: Signal Discarded SIG_NAME: TireAirLeakageRate, STATUS: No error, ACTION: Signal Discarded SIG_NAME: CTIWheelEndElectricalFault, STATUS: No error, ACTION: Signal Discarded SIG_NAME: CTITireStatus, STATUS: No error, ACTION: Signal Discarded SIG_NAME: CTIWheelSensorStatus, STATUS: No error, ACTION: Signal Discarded SIG_NAME: TireTemp, STATUS: No error, ACTION: Signal Discarded SIG_NAME: TirePress, STATUS: No error, ACTION: Signal Discarded SIG_NAME: CANHandThrottleSensortrack2, STATUS: No error, ACTION: Signal Discarded SIG_NAME: CANFootPedalSensortrack2, STATUS: No error, ACTION: Signal Discarded

I didnt get any error like "Error STATUS: Invalid start bit, ACTION: Signal Discarded" but still unable to associate it.

1) Associated dbf (generated by using DBC to DBF convertor) and got " xxx.dbf is not created for CAN.Since one of the message length exceeds 8 bytes"

2) Associated dbf (generated by using J1939 DBC to DBF convertor) and got " xxx.dbf is not created for CAN.Please load CAN related dbf file"

Please have a look into it and let me know.

kretb commented 12 years ago

I'm using 1.67 as well with the Peak USB and whenever I close the Programm, then I get the message "Unhandled exception in BUSMASTER. Would you like to save a Dump file?" I have stored this dumpfile and a busmaster.tempcfx I don't get this message when I'm using the v164

kretb commented 12 years ago

I'm also not able to convert a dbc file to a dbf File v167 and v164. When I start the conversion the a window pops-up with: "TODO: funktioniert nicht mehr Das Programm wird aufgrund eines Problems nicht richtig ausgeführt. Das Programm wird ......

willupowers commented 12 years ago

I'm also getting the same conversion issue with a J1939 DBC file that works in CANdb++. When I use the convert J1939 DBC to DBF and try to open in BUSMASTER, I get this error:

"DBF is not created for CAN. Please load CAN related DBF file."

Conversion Error Log

MSG_ID: 413335296 MSG_TYPE: X MSG_NAME: DM32 SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486442752 MSG_TYPE: X MSG_NAME: IT6 SIG_NAME: EngActualIgnTiming, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419321344 MSG_TYPE: X MSG_NAME: EGNR_AT1T1I SIG_NAME: AftSCROperatorInducementSeverity, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Aft1DEFtankLowlevelIndicator, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 418381827 MSG_TYPE: X MSG_NAME: ERC1_s03 SIG_NAME: IntendedRetarderPercentTorque, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: RetarderTorqueMode, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419241984 MSG_TYPE: X MSG_NAME: A1DOC SIG_NAME: Aftertreatment1DOCOutTemp, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Aftertreatment1DOCInTemp, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486441728 MSG_TYPE: X MSG_NAME: IT2 SIG_NAME: EngCylinderIgnTiming6, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: EngCylinderIgnTiming5, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 486441472 MSG_TYPE: X MSG_NAME: IT1 SIG_NAME: EngCylinderIgnTiming4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: EngCylinderIgnTiming3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: EngCylinderIgnTiming2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: EngCylinderIgnTiming1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419403001 MSG_TYPE: X MSG_NAME: RQST_STR_S249_dall SIG_NAME: Test_ID, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351329 MSG_TYPE: X MSG_NAME: DM2_s33 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351319 MSG_TYPE: X MSG_NAME: DM2_s23 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351073 MSG_TYPE: X MSG_NAME: DM1_s33 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351043 MSG_TYPE: X MSG_NAME: DM1_s3 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351063 MSG_TYPE: X MSG_NAME: DM1_s23 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419266560 MSG_TYPE: X MSG_NAME: DM28 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419267072 MSG_TYPE: X MSG_NAME: DM27 SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 418250753 MSG_TYPE: X MSG_NAME: ACL SIG_NAME: FunctionInstance, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ManufacturerCode, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: IdentityNumber, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 413073152 MSG_TYPE: X MSG_NAME: DM29 SIG_NAME: PermanentDTCs, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: PreviosulyMILonDTCs, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MILonDTCs, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: AllPendingDTCs, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: PendingDTCs, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419358462 MSG_TYPE: X MSG_NAME: TD SIG_NAME: LocalHourOffset, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: LocalMinuteOffset, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Minutes, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351040 MSG_TYPE: X MSG_NAME: DM1_s0 SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419280896 MSG_TYPE: X MSG_NAME: DM26 SIG_NAME: MisfireMonitoringComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ComprehensiveComptMonComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonComplete, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonEnabled, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419359744 MSG_TYPE: X MSG_NAME: VI SIG_NAME: VI_Delimiter, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: VIN_B17, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: VIN_B09_B016, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: VIN_B01_B08, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419355136 MSG_TYPE: X MSG_NAME: SOFT SIG_NAME: ASCIIfromHEX7, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ASCIIfromHEX6, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ASCIIfromHEX5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ASCIIfromHEX4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ASCIIfromHEX3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ASCIIfromHEX2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ASCIIfromHEX1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 418381839 MSG_TYPE: X MSG_NAME: ERC1_s15 SIG_NAME: IntendedRetarderPercentTorque, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: RetarderTorqueMode, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 417333281 MSG_TYPE: X MSG_NAME: CM1 SIG_NAME: EngAutoStrtEnSwitch, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419359488 MSG_TYPE: X MSG_NAME: CI SIG_NAME: UnitNumber_B09_B10, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SerialNumber_B17, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SerialNumber_B09_B16, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: CI_Delimiter_3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: CI_Delimiter_2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Model_B09_B10, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: CI_Delimiter_1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: UnitNumber_B01_B08, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SerialNumber_B01_B08, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Model_B01_B08, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: Make, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419352320 MSG_TYPE: X MSG_NAME: DM6 SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419352064 MSG_TYPE: X MSG_NAME: DM5 SIG_NAME: MisfireMonitoringSupport, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: HeatedCatalystMonSupp, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: MisfireMonitoringStatus, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: ComprehensiveComponentMonSupp, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351808 MSG_TYPE: X MSG_NAME: DM4 SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419280128 MSG_TYPE: X MSG_NAME: DM23 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419351296 MSG_TYPE: X MSG_NAME: DM2_s0 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419353600 MSG_TYPE: X MSG_NAME: DM12 SIG_NAME: FailureModeIdentifier5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: FailureModeIdentifier1, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN5, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN4, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN3, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN2, STATUS: Invalid Max or Min value., ACTION: Value Set to default SIG_NAME: SPN1, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419353088 MSG_TYPE: X MSG_NAME: DM10 SIG_NAME: TestIdentifierSupported, STATUS: Invalid Max or Min value., ACTION: Value Set to default

MSG_ID: 419279872 MSG_TYPE: X MSG_NAME: ATI2 SIG_NAME: ParticulateTrapIntakeGasTemp, STATUS: Invalid Max or Min value., ACTION: Value Set to default

RBEI-ArunKumar commented 12 years ago

The BUSMASTER application has separate viewers for CAN and J1939 database files. The CAN database file has to be opened/ associated in BUSMASTER application using menu option File-> Database -> Open... or File-> Database -> Associate.... The J1939 database file has to be opened/ associated in BUSMASTER application using menu option J1939 -> Database -> Open or J1939 -> Database -> Associate.

RBEI-Pramod commented 12 years ago

The PEAK issue is working fine in 1.6.8 Closing the bug.