Logging inside FR Cluster #840

Open RoSchCo opened 9 years ago

RoSchCo commented 9 years ago

Hello! Is it planned to implement Logging for FlexRay? If yes do you know when? Many thx in advance.

Nit2Nat commented 9 years ago

Hello, Apologize for the delay in response. Logging and further advanced features are planned for FlexRay in 2016. In principle development should be completed by Q2'16.

RoSchCo commented 9 years ago

Hello Nithin!

Ok, many thx for the information.

One additional question (I hope it is possible to do it via this way): We have one issue. We have stable FR communication with our ECU. If we have a planned reset on the ECU (so also of the FR communication) the BUSMASTER needs to be stopped and started again to get 'normal active'. If we use another tool which you maybe also know the communication gets 'normal active' w/o restarting. Is there something we have to set inside the options or is this a normal behavior?

Many thx in advance, Robert!

Von: Nithin Nath notifications@github.com An: rbei-etas/busmaster busmaster@noreply.github.com, Kopie: RoSchCo robert.scheruebl@continental-corporation.com Datum: 15.10.2015 12:43 Betreff: Re: [busmaster] Logging inside FR Cluster (#840)

Hello, Apologize for the delay in response. Logging and further advanced features are planned for FlexRay in 2016. In principle development should be completed by Q2'16. — Reply to this email directly or view it on GitHub.

Nit2Nat commented 9 years ago

Hello Robert,

Since we do not have real ECUs to try this out, this issue was not exactly reproducible. But in our test set-up, while running two instances of BUSMASTER where-in instance-1 of BUSMASTER acts as an ECU (Cold start node) and instance-2 as listener node, resetting instance-1, the instance-2 comes into "normal active" without restarting.

Regards Nithin

RoSchCo commented 9 years ago

Hello Nithin!

We have found out following. If both nodes

have 'sync node' the restart works. With 'Off' we see the bus before the reset but not after it even the bus is in "normal active". Is this normal?

Also 2 other topics we have found within FR;

Many thx for your support and have a nice weekend in advance, Robert!

Nithin Nath ---26.10.2015 12:14:09---Hello Robert, Since we do not have real ECUs to try this out, this issue was not exactly reproducibl

Von: Nithin Nath notifications@github.com An: rbei-etas/busmaster busmaster@noreply.github.com, Kopie: RoSchCo robert.scheruebl@continental-corporation.com Datum: 26.10.2015 12:14 Betreff: Re: [busmaster] Logging inside FR Cluster (#840)

Hello Robert, Since we do not have real ECUs to try this out, this issue was not exactly reproducible. But in our test set-up, while running two instances of BUSMASTER where-in instance-1 of BUSMASTER acts as an ECU (Cold start node) and instance-2 as listener node, resetting instance-1, the instance-2 comes into "normal active" without restarting. Regards Nithin — Reply to this email directly or view it on GitHub.