What steps will reproduce the problem?
1.
2.
3.
What is the expected output? What do you see instead?
Please use labels and text to provide additional information.
Test A.2.4 Stream-based Transport_4 fails. The expected output from RFC 4465
is MESSAGE_TOO_SHORT; the ‘MSG: INVALID_CODE_LOCATION’ is generated from my
wrapper tests but there is no NACK. Doubango test does not report any MSG or
ERROR but just xoutput: NO.
Output from my tests…
================================================
=== Testing A.2.4. Stream-based Transport_5 ===
================================================
***ERROR: function: "initStateless()"
file: ".\src\tcomp_message.c"
line: "170"
MSG: INVALID_CODE_LOCATION
***ERROR: function: "tcomp_decompressordisp_internalDecompress()"
file: ".\src\tcomp_decompressordisp.c"
line: "183"
MSG: Failed to create new sigcomp message.
xoutput: NO
xcycles: YES
output size: 0
=== A.2.4. Stream-based Transport_5 status: FAIL ===
=====================================================
Output from Doubango tests…
=== Testing A.2.4. Stream-based Transport_5 ===
xoutpout: NO
xcycles: YES
output size: 0
Original issue reported on code.google.com by boss...@yahoo.fr on 8 Jan 2013 at 11:41
Original issue reported on code.google.com by
boss...@yahoo.fr
on 8 Jan 2013 at 11:41