Device not booting up on active HAN port #42

Open mijak99 opened 1 week ago

mijak99 commented 1 week ago

Hi,

I have just received my device (https://www.m.nu/sensorer-wifi/elmatare-for-p1-han-port-med-wifi)

Connected it to a Kaifa MA304H4D with activated HAN-port, but nothing happens. The LED does not light up. For clarity:

Since the MA304 is listed as a supported meter, I am assuming something is off? Any ideas on how I can troubleshoot this issue?

If this is the wrong place to ask, or if more information is needed, let me know.

remne commented 4 days ago

Hi,

MA304H4D is a M-Bus meter, and not P1-meter as far as I know. P1IB only works with MA304 meters that have a P1 interface. If you take a look at the meter, there is probably a "M-Bus"-label somewhere on it, indicating its not a P1 meter, instead it uses HAN-NVE (Norwegian standard).

Regards, Andreas

mijak99 commented 4 days ago

Thanks for the response. FYI, I can confirm that there is an M-bus marking on the meter.

I thought that the Norwegian standard was using RJ45, but this one has an RJ12.