rg-engineering / ioBroker.sbfspot

reads data from SMA power inverters using sbfspot
MIT License
6 stars 4 forks source link

missing EToday in DB on some inverters #30

Open rg-engineering opened 4 years ago

rg-engineering commented 4 years ago

sDB structure is Timestamp; Serial; PDC1; PDC2; IDC1, IDC2; UDC1; UDC2; PAC1, PAC2; PAC3; IAC1; IAC2; IAC3; UAC1; UAC2; UAC3; EToday, ETotal; Frequency; OperatingTime; FeedInTime; BT_Signal; Status; GridRelay; Temperature

and is filled with

1584634502| 4711|44|99|0.1|0.198|444.19|501.47|39|43|42|0.385|0.403|0.432|222.72|225.16|226.2| 0|903639|49.99|611.446|583.194|0.0|OK|Closed|0.0

see Forum: https://forum.iobroker.net/topic/5555/neuer-adapter-sma-wechselrichter-mit-sbfspot/143

sbf- commented 4 years ago

See also this issue Still no fix, in some cases a firmware upgrade might help.

SBFspot commented 2 years ago

This is fixed in SBFspot V3.8.0 Current version is 3.9.5