No power ON under batery t-beam 1.2 AXP2101 #116

Closed dcardenosa closed 6 months ago

dcardenosa commented 6 months ago

Hi I have 2 T-Beams 1.2 with AXP2101 that work ok under usb power but doesn't under battery power. They don´t power up pressing the pwr button. The button works on usb power. With usb power they measure the battery voltake ok and show (charging) message. If I disconnect the usb cable the t-beam powers off.

With the Meshtastic fw the batery power works fine on those boards.

I set the environment on vscode to "ttgo-t-beam-v1_2". Cleaned up the vscode environment few times and make a clean git clone of the repository.

Not sure what´s the problem. :S

I also have 2 T-Beams 1.1 that work ok on batery power.

Thanks David EA1FAQ

imagen

imagen

richonguzman commented 6 months ago

Hi

Sometimes AXP2101 power management chip needs a reboot

Take out the battery and put them back on (without usb)

This may solve this issue

dcardenosa commented 6 months ago

Yes!!! The problem was solved! Thanks!

David EA1FAQ