Tracking is stopped suddenly #20

Closed JuergenTerpe closed 2 years ago

JuergenTerpe commented 2 years ago

Describe the bug The NEQ6 suddenly stops tracking from time to time, during Autofocus or Plate solving or inside an image sequence.

To Reproduce Happens several times during a night, but is not reproducible directly.

Expected behavior The tracking should not stop unless tracking is stopped by the user.

Desktop (please complete the following information):

In the attached log the error occurs at 23:23, the last successful image was created at 23:19. After that time imaging failed until I checked and tried to bring it back to running around 03:00 - but then I needed to stop imaging due to weather conditions. GSSessionLog2021-12-25-16.txt

rmorgan001 commented 2 years ago

Log shows lot's parse errors from the mount "ErrInvalidData, Response Parse Error: =80vCA2". The v is an invalid character. More than likely it's a loose or bad cable. You will need to get this fixed then re-evaluate the issue. You also ran into the limits at 00:51:00 which was set to turn off tracking. Go to the website and manual to review the limits settings. https://sites.google.com/view/greenswamp/gsserver/help-videos