robertsonics / WTConfig

Tsunami / WAV Trigger Unified Configurator Utility
4 stars 4 forks source link

False triggering in active mode WTconfig #5

Open golkit1 opened 1 year ago

golkit1 commented 1 year ago

I'm triggering the wav trigger using a movement sensor that goes HIGH when movement is detect. I set the init file as follow:

Trigger: 1 Hardware Interface: Active Type: Edge Function: Normal Invert: tick Re-trigger: untick Polyphonic: untick loop: untick

most of the time it works as it should: new triggers will not restart the track until finished. Sometime it happens that new triggers are indeed restarting the track, which is not desired. What could be the issue?

robertsonics commented 1 year ago

Please ensure that you are using the most recent firmware which, is v1.34, available here:

https://www.robertsonics.com/downloads

golkit1 commented 1 year ago

I tick the "Lock voice" box and it seems to solved it. Does it make sense? Regarding the latest firmware. Is it possible to update via the init file? I don't have USB to TTL serial adaptor - is there other way I can update the firmware?

robertsonics commented 1 year ago

If locking the track does it, then yes that's another way to accomplish what you want. I do think the fact that the other method occasionally does not work is a bug that was fixed in a subsequent firmware update.

Unfortunately, you do need a USB-to-TTL Serial adaptor to update the firmware. The update is only possible through the STM serial bootloader.