Closed gabrielenava closed 2 years ago
I found several connectors with problems: the E11 cable on the EB11 had a problem on the shield. The 9N1 cable on the 3B10 can2 had a nearly torn cable The 9N2 strain cable on the EB9 had the red cable nearly torn. I restored the wiring and turned on the setup to test it.
Hi @Uboldi80, after your intervention the issue happened again when the turbines were ON. Now the issue is more frequent when there's relatively high temperature.
We also noted that the 2 errors mentioned above (Strain timeout and hardware fault) happen at the same time.
Here are the logs from yesterday and today's experiments (When the turbines where ON):
Hi @Uboldi80, after your intervention the issue happened again when the turbines were ON. Now the issue is more frequent when there's relatively high temperature.
We also noted that the 2 errors mentioned above (Strain timeout and hardware fault) happen at the same time.
Here are the logs from yesterday and today's experiments (When the turbines where ON):
Hi @Uboldi80, I wrote the above comment with iRonCub account. Sorry it was on the fly.
Device name 🤖
iCubGenova04
Request/Failure description
While the robot is balancing on two feet the right ankle joints sometimes go in hardware fault. There are two errors messages related to right ankle board in the yarplogger:
1) strain timeout 2) AEA encoder invalid data
Detailed context
here the full logger:
log_icub-head_yarprobotinterface_45612.txt
Additional context
No response
How does it affect you?
It affects the experiments programmed for the iRonCub rush.
cc @DanielePucci