Closed xEnVrE closed 11 months ago
Hi @xEnVrE, there was a calibration problem on the thumb proximal.
I recalibrated the joint and tested the robot.
It works properly now!
Remember to update the configuration files, here the PR:
Since the robot has been tested, I am closing the issue, if you have any problems regarding this issue, feel free to reopen it.
cc @sgiraz
Thanks a lot @AntonioConsilvio !
Robot Name 🤖
iCubGenova11 S/N:050
Request/Failure description
After #1647, @AntonioAzocar noticed that the left thumb oppose of the robot was not calibrating and the encoder readings were strange and out of scale.
Detailed context
The following screenshot, taken from #1647, shows the status of the thumb oppose joint after the failed calibration:
Additional context
No response
How does it affect you?
No response