Robot Name 🤖

iCubGenova11 S/N:050

Request/Failure description

As per title, while running some experiments the proximal tendon of the right thumb broke.

Detailed context

As per title, while running some experiments the proximal tendon of the right thumb broke. I cannot run my experiments and I have an upcoming deadline for a paper submission.

Additional context

No response

How does it affect you?

I cannot run my experiments and I have an upcoming deadline for a paper submission.

github-actions[bot] commented 10 months ago

⚠️ Detected missing mandatory information

Hi @fedeceola 👋🏻

Some of the following points need your attention.

You are required to:

Please, mark the points above as solved once done. [^1]: To get to know the allowed options for the dropdown fields, you may peruse the template.

xEnVrE commented 10 months ago

cc @sgiraz @GiacomoVassallo13 @AntonioConsilvio

GiacomoVassallo13 commented 10 months ago

@fedeceola @xEnVrE . The thumb proximal joint has been replaced and is ready to be tested. I attend a feedback.

cc: @sgiraz @Fabrizio69

xEnVrE commented 10 months ago

This has been tested. Closing.

cc @fedeceola

sgiraz commented 10 months ago

Just to clarify,

@AntonioConsilvio and I found the mais board of the right hand, non properly connected.

image

image

We have to pay attention to the wires when re-closing the covers (especially on the hands)

Cc @GiacomoVassallo13