iCubGenova11 S/N:050 – Right thumb proximal tendon broken #1702

Closed fedeceola closed 3 months ago

fedeceola commented 6 months ago

Robot Name 🤖

iCubGenova11 S/N:050

Request/Failure description

As per title, while running some experiments the proximal tendon of the right thumb broke.

Detailed context

As per title, while running some experiments the proximal tendon of the right thumb broke. I cannot run my experiments and I have an upcoming deadline for a paper submission.

Additional context

No response

How does it affect you?

I cannot run my experiments and I have an upcoming deadline for a paper submission.

github-actions[bot] commented 6 months ago

⚠️ Detected missing mandatory information

Hi @fedeceola 👋🏻

Some of the following points need your attention.

You are required to:

Please, mark the points above as solved once done. [^1]: To get to know the allowed options for the dropdown fields, you may peruse the template.

fedeceola commented 5 months ago

Hi, are there any plans to fix this? I'd need to do some tests by the end of the week.

sgiraz commented 5 months ago

Hi @fedeceola,

Today @GiacomoVassallo13 started the maintenance activity on iCubGenova11, further updates will follow tomorrow morning

cc @AntonioConsilvio

fedeceola commented 5 months ago

Hi, with @AntonioAzocar we just tried to run the robot. It cannot complete the calibration of the right thumb. The motor of the proximal joint is moving but the finger doesn't close. Furthermore, the tactile sensor of the thumb is not working.

cc @sgiraz @GiacomoVassallo13 @AntonioConsilvio

GiacomoVassallo13 commented 5 months ago

Hi. The rigth prossimal yoint of thumb has been replaced. The yoint was been tested by @fedeceola. cc: @sgiraz

fedeceola commented 4 months ago

Hi, actually I couldn't test the joint because, due to the issue in #1723, the right hand couldn't finish the calibration.

AntonioConsilvio commented 4 months ago

Hi @fedeceola! Today I checked the status of the robot.

All tendons were intact, but the right thumb proximal joint didn't work because the connector was quite detached from the MC4-PLUS.

Now all joints are working properly:

https://github.com/robotology/icub-tech-support/assets/114915464/2b54c7b3-6c5f-4d0c-9bfc-72cb78d86fa1

In addiction I fixed the configuration files, see the PR:

cc @sgiraz

fedeceola commented 4 months ago

Hi @AntonioConsilvio, thanks! I'll do some tests these days!

cc @lornat75

fedeceola commented 3 months ago

Hi, yesterday and today I did some tests. The thumb is working. I think that we can close the issue. Thanks!