iCubErzelli01 S/N:032 – Fingers on the left-arm not working properly #1710

Closed ddetommaso closed 5 months ago

ddetommaso commented 5 months ago

Robot Name 🤖

iCubErzelli01 S/N:032

Request/Failure description

We have encountered issues on fingers of the left-arm, specifically related to thumb and pinky joints.

Detailed context

During calibration the fingers often get stuck. Moreover, even when the calibration is successful, the little fingers are not moving from yarpmotorgui the interface (motor and encoders seem fine).

Additional context

log_icub-head_yarprobotinterface_3025.zip

image

https://github.com/robotology/icub-tech-support/assets/3440640/4bcdfdbd-5cdb-4a13-8a1d-7e7b2fd72d42

How does it affect you?

High impact. The robot is currently in use for an experimental protocol and we needed to cancel participants.

AntonioConsilvio commented 5 months ago

Hi @ddetommaso, a quick test. The solution may be simpler than expected. Specifically it is to make sure the configuration files are aligned on this robots-configuration master commit:

In particular, this PR had originated from the last intervention performed to iCuberzelli01 (see issue).

Let us know as soon as you can!

cc @sgiraz

ddetommaso commented 5 months ago

Hi @AntonioConsilvio

I can confirm that the configuration files are correctly aligned with the ones in the PR. The pinky fingers are still not correctly working, probably there is a calibration issu.

sgiraz commented 5 months ago

Hi @ddetommaso,

The maintenance activity is scheduled for tomorrow!

cc @GiacomoVassallo13 @AntonioConsilvio

AntonioConsilvio commented 5 months ago

Hi @ddetommaso. Yesterday me and @GiacomoVassallo13, after several tests, found the flat cable that connect the pinky motor the MC4-PLUS EB26 damaged. So, we cut off most of the damaged flat and soldered a new one.

The robot seemed to works properly! But we are waiting for feedback before proceeding with closing the issue.

We also found once that the thumb distal was not calibrating, but the problem was solved by restarting the motors. For now talking with @ddetommaso it was considered a non-urgent or blocking issue, so it was agreed not to investigate further for now.

cc @sgiraz

sgiraz commented 5 months ago

Hi @ddetommaso,

Do you have any feedback to share w/ us?

ddetommaso commented 5 months ago

Hi @sgiraz

I am still waiting to provide our feedback for a couple of days of testing.

Thank you

ddetommaso commented 5 months ago

Hi guys,

we can close this. The issue with the pinky is fixed

sgiraz commented 5 months ago

Thanks for your feedback @ddetommaso.

Closing!