The optical encoder connector on the right arm sometimes disconnects during tests.
Detailed context
The connector is loose, a small movement can cause it to disconnect, which in turn creates strange arm movements. Usually it only disconnects for a moment, and it doesn't seem to send the motor into fault. Most likely related to the fix competed yesterday, see #1765.
Hi @evelyd, the loose cable was the RA_E1 that connect LCORE5 of the right roll to the 2FOC 1B0. I fixed the cable crimping again all wires. The robot has been tested and it works properly now!
Robot Name 🤖
ergoCub 1.1 S/N:001
Request/Failure description
The optical encoder connector on the right arm sometimes disconnects during tests.
Detailed context
The connector is loose, a small movement can cause it to disconnect, which in turn creates strange arm movements. Usually it only disconnects for a moment, and it doesn't seem to send the motor into fault. Most likely related to the fix competed yesterday, see #1765.
Additional context
robot_logger_device_2024_03_07_11_11_24.md
https://github.com/robotology/icub-tech-support/assets/17877131/c8a16b83-a6f1-4cc2-a07f-65f13ddedcdf
How does it affect you?
No response