Open ddetommaso opened 2 months ago
After further test we noticed that the issue is occurring quite systematically having the two yarpdev of the camera (right and left) running at the same time on the icub-head.
At this point we would need to schedule your intervention possibly on the 7th of October.
Hi @ddetommaso, unfortunately, we will need October 7th to carry out a status check and pack the robot along with all the necessary materials for the trip to Stanford.
As a result, we won’t be able to schedule the intervention on that day.
However, we will try to come to Erzelli on one of the other days next week to perform the intervention. Would there be someone available as contact?
Hi @AntonioConsilvio
ok, thanks. Please refer to @mmwozniak who's going to use the robot in the next following weeks and set a suitable date with him.
cc @AgnieszkaWykowska
Hi @mmwozniak, we are available tomorrow for the intervention. We will come in the morning around 8:30.
We will already be autonomous to start the intervention. We will then need you to join us for the robot test.
Thank you for information. I will be available to test the robot from around 10:00.
Additional information: the robot also occasionally has problems with the neck - when turning off the yarp robot interface its head goes to the back and right, and then these motors have problems when starting again.
Robot Name 🤖
iCubErzelli01 S/N:032
Request/Failure description
We initially noticed two consecutive robot crash (robot falling down) in two different sessions. After further investigation we noticed that the head is restarting and keeps restarting in some conditions.
Detailed context
We tested the status of the robot head running only yarpdev to see video streaming of the camera without launching the yarprobotinterface. In this condition the robot head after some minutes restarts. The issue seems get worse if also the motors are ON.
Additional context
syslog.txt
How does it affect you?
We must finalize a new experimental study with the robot within this week.