iCubGenova11 S/N:050 โ€“ Right ring finger doesn't close well #1916

Open martinaxgloria opened 1 week ago

martinaxgloria commented 1 week ago

Robot Name ๐Ÿค–

iCubGenova11 S/N:050

Request/Failure description

During some grasping tests, I found out that the ring finger of the right hand doesn't close as expected.

Edit: we also noticed that the thumb oppose moves in a strange way when calibrating, causing the calibration to fail for most of the joints of the right hand

Detailed context

The ring finger closes before the pinky, so the grasp is not performed optimally.

Additional context

No response

How does it affect you?

We are not able to perform the Stanford demo as well.

cc @Nicogene

github-actions[bot] commented 1 week ago

โš ๏ธ Detected missing mandatory information

Hi @martinaxgloria ๐Ÿ‘‹๐Ÿป

Some of the following points need your attention.

You are required to:

Please, mark the points above as solved once done. [^1]: To get to know the allowed options for the dropdown fields, you may peruse the template.

fbiggi commented 4 days ago

Image

image

image

@Fabrizio69 @AntonioConsilvio

maggia80 commented 4 days ago

@Gandoo puoi verificare il motore prossimale del pollice destro? Guarderei se il connettore รจ rovinato e proverei a farlo muovere con la jogger.

martinaxgloria commented 4 days ago

Until this morning, the issue about the ring/pinky seemed to be solved, but after a few calibrations of the hand, the problem of the tendon appeared again.

cc @maggia80 @Nicogene @pattacini @Fabrizio69

Gandoo commented 4 days ago

ho risaldato i fili sui 2 Fingertip che si erano staccati durante la sostituzione dei tendini.

Image

cc @fbiggi @martinaxgloria @Fabrizio69

Gandoo commented 4 days ago

C'era un problema con l'abduzione del pollice Destro, si accostava tutto al palmo e non permetteva la riuscita della calibrazione. Ho verificato il cablaggio e movimento con la Jogger e alla fine mi si รจ staccato il filo bianco del sensore di Hall sul connettore Molex della scheda. Ricrimpato i fili, sostituito il Molex e riprovato a fare i movimento con jogger e funziona perfettamente. In seguito @martinaxgloria ha verificato con @AntonioConsilvio i valori e in seguito la calibrazione ha cominciato ad andare a buon fine.