Open rogerlew opened 3 years ago
Descriptions of WEPP Hillslope Pass File Parameters
***Hillslope pass file info.****
Line 1: Hillslope input climate file - string (hillcli) Line 2: a) Maximum number of simulation years - integer (tmpnyr) b) Beginning year of watershed climate file - integer (tmpbyr) Line 3: Hillslope area - real (harea) Line 4: a) Number of particle size - integer (npart) b) Particle diameter for each particle class - real (tmpdia(i), i=1,ncpart)
NoteLine 5 is repeated for each simulated day depending on if there was "NO EVENT", "EVENT", AND "SUBEVENT" header.
Line 5: a) “NO EVENT” header b) year - integer (year) c) day - integer (day)
OR
Line 5: a) “EVENT” header b) year - integer (year) c) day - integer (day) Line 6: runoff duration (seconds) - integer (tmpdur) Line 7: time of concentration (hours) - real (tmptcs) Line 8: alpha value (for EPIC peak calculation) - real (tmpalp) Line 9: runoff depth (m) - real (tmprof) Line 10: runoff volume (m3 ) - real (tmpvol) Line 11: subsurface runoff depth (m) - real (tmpsbf) Line 12: subsurface runoff volume (m3) - real (tmpsbv) Line 13: tile-drain runoff depth (m) - real (tmpdrf) Line 14: tile-drain runoff volume (m3) - real (tmpdrv) Line 15: runoff peak (m3/s) - real (tmppkr) Line 16: soil detachment (kg) - real (tmpdet) Line 17: soil deposition (kg) - real (tmpdep) Line 18: sediment concentration for each particle class (kg/m3 ) - real (tmpsed(i), i = 1, npart) Line 19: fraction of sediment in each particle class - real (tmpflw(i), i = 1,npart) Line 20: groundwater baseflow volume (m3) - real (tmpgwbfv) Line 21: groundwater deep seepage volume (m3) - real (tmpgwdsv)
OR
Line 5: a) "SUBEVENT" header
b) year - integer (year)
c) day - integer (day)
NoteIf there is an event, lines 11 through 14 and 20 through 21 are added, which are:
Line 11: subsurface runoff depth (m) - real (tmpsbf)
Line 12: subsurface runoff volume (m3) - real (tmpsbv)
Line 13: tile-drain runoff depth (m) - real (tmpdrf)
Line 14: tile-drain runoff volume (m3) - real (tmpdrv)
Line 20: groundwater baseflow volume (m3) - real (tmpgwbfv)
Line 21: groundwater deep seepage volume (m3) - real (tmpgwdsv)
To Do
Potential Tests Sites
Murphy Creek Reynolds Creek Telegraph Fire (Arizona) Sites used by Osama/Fred