I'm going to consolidate a couple small documentation issues related to the calibration section (2.2) of the user manual here.
Acceptance blockers:
[x] Incomplete initial guess directions (2.2.2 Initial Calibration step 2). The directions ask for initial guesses for camera position, but the new camera file is also generated with a value of f = 1. f does not appear to change (stays at 1) when running the calibration - this leads to high reprojection errors and calibrations that don't converge within reasonable time.
Other:
[x] The calibration_points_gui workflow option is mentioned in 2.2 Calibration guide, but not in 2.1.1 The workflow.py script, which only lists 7 options for the workflow command. Please also check for other hidden workflow options and include a complete list in 2.1.1.
[x] 2.2.2 Initial Calibration step 3 mentions choosing 6 calibration points for initial calibration - in addition to having asymmetry in point selection, the 6 points also shouldn't all be coplanar. I'd encourage you to mention this specifically in the docs. It's also a little confusing that the example folder has more than 6 points for each camera for this step (maybe say "at least 6 points" in the docs?)