rusefi / proteus-Honda-K-125-adapter

1 stars 1 forks source link

VTC control needs diode fix #29

Open rusefillc opened 2 years ago

rusefillc commented 2 years ago

i have duty cycle change from 5% to 95% of VTC / HS2 and no results on shaft position

rusefillc commented 2 years ago

this was SW configuration issue, not HW issue

rusefillc commented 2 years ago

@mck1117 says

high side outputs have no diode, so it will make lots of heat and have poor control Should work better with less duty cycle Diode from gnd to switched pin Non-stripe goes to gnd Stripe goes to vvt

rusefillc commented 2 years ago

hello diode to +12MR, should go to GND

image

rusefillc commented 2 years ago

between better PID settings and flipped diode VVT/VTC control is much happier

TODO fix diode on adapter