at the moment I'm comparing results from JPower to MatPower, and for reference I'm using the:
9-Bus-Grid
It's delivered with MatPower and JPower.
Example differences
First of all these two grids differ in their matrixes, some values were different (I didn't kept track) and I changed them. Next step is now comparing the results (see below).
Problems so far:
As you can see, the maximum Q Losses line, is the wrong one
The Branch Data has a sign error in the Q Losses table (on every value!)
The Bus Data is completly messed up.
This all may result from the sign error in the Branch Data table...
JPower
================================================================================
| System Summary |
================================================================================
How many? How much? P (MW) Q (MVAr)
--------------------- ------------------- ------------- -----------------
Buses 9 Total Gen Capacity 820,0 -900,0 to 900,0
Generators 3 On-line Capacity 820,0 -900,0 to 900,0
Committed Gens 3 Generation (actual) 320,0 34,9
Loads 3 Load 315,0 115,0
Fixed 3 Fixed 315,0 115,0
Dispatchable 0 Dispatchable -0,0 of -0,0 -0,0
Shunts 0 Shunt (inj) -0,0 0,0
Branches 9 Losses (I^2 * Z) 4,95 -51,31
Transformers 0 Branch Charging (inj) - 131,4
Inter-ties 9 Total Inter-tie Flow 565,0 170,0
Areas 1
Minimum Maximum
------------------------- --------------------------------
Voltage Magnitude 0,958 p.u. @ bus 9 1,003 p.u. @ bus 6
Voltage Angle -4,35 deg @ bus 9 9,67 deg @ bus 2
P Losses (I^2*R) - 2,46 MW @ line 8-9
Q Losses (I^2*X) - -0,81 MVAr @ line 6-7
================================================================================
| Bus Data |
================================================================================
Bus Voltage Generation Load
# Mag(pu) Ang(deg) P (MW) Q (MVAr) P (MW) Q (MVAr)
----- ------- -------- -------- -------- -------- --------
1 1,000 0,000 - - -215,86* -72,21*
2 1,000 9,669 - - -215,86* -72,21*
3 1,000 4,771 - - -215,86* -72,21*
4 0,987 -2,407 - - -215,86* -72,21*
5 0,975 -4,017 - - -125,86* -42,21*
6 1,003 1,926 - - -215,86* -72,21*
7 0,986 0,622 - - -115,86* -37,21*
8 0,996 3,799 - - -215,86* -72,21*
9 0,958 -4,350 - - -90,86* -22,21*
-------- -------- -------- --------
Total: 319,95 34,88 315,00 115,00
================================================================================
| Branch Data |
================================================================================
Brnch From To From Bus Injection To Bus Injection Loss (I^2 * Z)
# Bus Bus P (MW) Q (MVAr) P (MW) Q (MVAr) P (MW) Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- --------
0 1 4 71,95 24,07 -71,95 -20,75 0,000 -3,32
1 4 5 30,73 -0,59 -30,55 -13,69 0,174 -0,94
2 5 6 -59,45 -16,31 60,89 -12,43 1,449 -6,31
3 3 6 85,00 -3,65 -85,00 7,89 0,000 -4,24
4 6 7 24,11 4,54 -24,01 -24,40 0,095 -0,81
5 7 8 -75,99 -10,60 76,50 0,26 0,506 -4,29
6 8 2 -163,00 2,28 163,00 14,46 0,000 -16,74
7 8 9 86,50 -2,53 -84,04 -14,28 2,465 -12,40
8 9 4 -40,96 -35,72 41,23 21,34 0,266 -2,26
-------- --------
Total: 4,955 -51,31
MatPower
================================================================================
| System Summary |
================================================================================
How many? How much? P (MW) Q (MVAr)
--------------------- ------------------- ------------- -----------------
Buses 9 Total Gen Capacity 820.0 -900.0 to 900.0
Generators 3 On-line Capacity 820.0 -900.0 to 900.0
Committed Gens 3 Generation (actual) 320.0 34.9
Loads 3 Load 315.0 115.0
Fixed 3 Fixed 315.0 115.0
Dispatchable 0 Dispatchable -0.0 of -0.0 -0.0
Shunts 0 Shunt (inj) -0.0 0.0
Branches 9 Losses (I^2 * Z) 4.95 51.31
Transformers 0 Branch Charging (inj) - 131.4
Inter-ties 0 Total Inter-tie Flow 0.0 0.0
Areas 1
Minimum Maximum
------------------------- --------------------------------
Voltage Magnitude 0.958 p.u. @ bus 9 1.003 p.u. @ bus 6
Voltage Angle -4.35 deg @ bus 9 9.67 deg @ bus 2
P Losses (I^2*R) - 2.46 MW @ line 8-9
Q Losses (I^2*X) - 16.74 MVAr @ line 8-2
================================================================================
| Bus Data |
================================================================================
Bus Voltage Generation Load
# Mag(pu) Ang(deg) P (MW) Q (MVAr) P (MW) Q (MVAr)
----- ------- -------- -------- -------- -------- --------
1 1.000 0.000* 71.95 24.07 - -
2 1.000 9.669 163.00 14.46 - -
3 1.000 4.771 85.00 -3.65 - -
4 0.987 -2.407 - - - -
5 0.975 -4.017 - - 90.00 30.00
6 1.003 1.926 - - - -
7 0.986 0.622 - - 100.00 35.00
8 0.996 3.799 - - - -
9 0.958 -4.350 - - 125.00 50.00
-------- -------- -------- --------
Total: 319.95 34.88 315.00 115.00
================================================================================
| Branch Data |
================================================================================
Brnch From To From Bus Injection To Bus Injection Loss (I^2 * Z)
# Bus Bus P (MW) Q (MVAr) P (MW) Q (MVAr) P (MW) Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- --------
1 1 4 71.95 24.07 -71.95 -20.75 0.000 3.32
2 4 5 30.73 -0.59 -30.55 -13.69 0.174 0.94
3 5 6 -59.45 -16.31 60.89 -12.43 1.449 6.31
4 3 6 85.00 -3.65 -85.00 7.89 0.000 4.24
5 6 7 24.11 4.54 -24.01 -24.40 0.095 0.81
6 7 8 -75.99 -10.60 76.50 0.26 0.506 4.29
7 8 2 -163.00 2.28 163.00 14.46 0.000 16.74
8 8 9 86.50 -2.53 -84.04 -14.28 2.465 12.40
9 9 4 -40.96 -35.72 41.23 21.34 0.266 2.26
-------- --------
Total: 4.955 51.31
How can you run this project successfully? There are not parallel colt version of 0.9.5 presented in the web. hope to receive your answer, its important for my research. thank you!!!
Hi,
at the moment I'm comparing results from JPower to MatPower, and for reference I'm using the: 9-Bus-Grid It's delivered with MatPower and JPower.
Example differences
First of all these two grids differ in their matrixes, some values were different (I didn't kept track) and I changed them. Next step is now comparing the results (see below).
Problems so far:
This all may result from the sign error in the Branch Data table...
JPower
MatPower